Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

7T MRI in focal epilepsy with unrevealing conventional field strength imaging

De Ciantis, Alessio, Barba, Carmen, Tassi, Laura, Cosottini, Mirco, Tosetti, Michela, Costagli, Mauro, Bramerio, Manuela, Bartolini, Emanuele, Biagi, Laura, Cossu, Massimo, Pelliccia, Veronica, Symms, Mark R., Guerrini, Renzo · 2016 · Epilepsia

Abstract

Summary: Objective: To assess the diagnostic yield of 7T magnetic resonance imaging (MRI) in detecting and characterizing structural lesions in patients with intractable focal epilepsy and unrevealing conventional (1.5 or 3T)MRI. Methods: We conducted an observational clinical imaging study on 21 patients (17 adults and 4 children) with intractable focal epilepsy, exhibiting clinical and electroencephalographic features consistent with a single seizure‐onset zone (SOZ) and unrevealing conventional MRI. Patients were enrolled at two tertiary epilepsy surgery centers and imaged at 7T, including whole brain (three‐dimensional [3D] T 1‐weighted [T1W] fast‐spoiled gradient echo (FSPGR), 3D susceptibility‐weighted angiography [SWAN], 3D fluid‐attenuated inversion recovery [FLAIR]) and targeted imaging (2D T 2*‐weighted dual‐echo gradient‐recalled echo [GRE] and 2D gray–white matter tissue border enhancement [TBE] fast spin echo inversion recovery [FSE‐IR]). MRI studies at 1.5 or 3T deemed unrevealing at the referral center were reviewed by three experts in epilepsy imaging. Reviewers were provided information regarding the suspected localization of the SOZ. The same team subsequently reviewed 7T images. Agreement in imaging interpretation was reached through consensus‐based discussions based on visual identification of structural abnormalities and their likely correlation with clinical and electrographic data. Results: 7T MRI revealed structural lesions in 6 (29%) of 21 patients. The diagnostic gain in detection was obtained using GRE and FLAIR images. Four of the six patients with abnormal 7T underwent epilepsy surgery. Histopathology revealed focal cortical dysplasia (FCD) in all. In the remaining 15 patients (71%), 7T MRI remained unrevealing; 4 of the patients underwent epilepsy surgery and histopathologic evaluation revealed gliosis. Significance: 7T MRI improves detection of epileptogenic FCD that is not visible at conventional field strengths. A dedicated protocol including whole brain FLAIR and GRE images at 7T targeted at the suspected SOZ increases the diagnostic yield.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/epi.13313

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 160

Metadata

Authors
De Ciantis, A., Barba, C., Tassi, L., Cosottini, M., Tosetti, M., Costagli, M., Bramerio, M., Bartolini, E., Biagi, L., Cossu, M., Pelliccia, V., Symms, M. R., & Guerrini, R.
Venue
Epilepsia
Publisher
Wiley
Published
2016-01-18
Volume
57
Issue
3
Pages
445-454
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W2297732712
Cited by
160
References
1
FWCI
12.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 7T MRI in focal epilepsy with unrevealing conventional field strength imaging. https://app.cochat.ai/papers/10.1111/epi.13313
The paper
De Ciantis, A., Barba, C., Tassi, L., Cosottini, M., Tosetti, M., Costagli, M., Bramerio, M., Bartolini, E., Biagi, L., Cossu, M., Pelliccia, V., Symms, M. R., & Guerrini, R. (2016). 7T MRI in focal epilepsy with unrevealing conventional field strength imaging. Epilepsia. https://doi.org/10.1111/epi.13313

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.