CoChat

Reliability, agreement and variability of a markerless computer vision algorithm for equine gait analysis under field conditions

Key, Karsten, Berg, Katja, Kirkegaard, Jakob, Andresen, Kristian Ringkjær, Skov Hansen, Sabrina · 2026 · Equine Veterinary Journal
Cited by 2

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Computer vision‐based algorithms offer accessible alternatives for equine gait analysis but require thorough assessment under diverse conditions. Objectives: To evaluate a proprietary vision‐based algorithm's reliability in measuring vertical displacement signals (VDS) at the eye, withers and croup, alongside groundline estimation, for horses trotting on straight lines and circles under field conditions. Study Design: Cross‐sectional comparative study evaluating agreement, variability and reliability of a markerless computer vision algorithm. Methods: We obtained 67 handheld iPhone recordings from 37 horses. A vision‐based algorithm and independent manual annotation produced 2D anatomical keypoints on all frames of the recordings, which were processed to estimate a groundline and compute VDS and stride‐based maxima (Maxdiff) and minima (Mindiff) vertical differences. Mean signed error (MSE), mean absolute error (MAE) and Bland–Altman plots were used to compare detected and annotated data. Results: The frame level vertical keypoint accuracy was 4.5 mm (eye), 5.5 mm (croup) and 11.8 mm (withers), and the manual annotation error was averaged at 2.7 mm. At the stride level ( n = 1556), the overall mean absolute errors (MAEs) for both Maxdiff and Mindiff were 4.3 mm. The eye keypoint exhibited the lowest errors (2.9 mm Maxdiff, 3.0 mm Mindiff), while the withers error was 5.5 mm for both Maxdiff and Mindiff, and the croup showed 4.3 mm (Maxdiff) and 4.4 mm (Mindiff). Trial‐level ( n = 67) analysis, with below optimal number of strides per trial in this study, revealed lower overall absolute differences (Eye: 2.3 mm, Withers: 3.7 mm, Croup: 2.7 mm), indicating consistent performance across multiple strides. Subjective lameness scoring aligned with objective measures with some variation. Main Limitations: Groundline estimation accuracy was stress‐tested on treadmill data in another study. Further clinical comparison with established gait analysis systems is recommended. Conclusions: The algorithm robustly measured vertical displacements under varied conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/evj.70109

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 31

  1. 10.1136/vr.159.11.346 · DOI · Paper page
  2. 10.1016/j.tvjl.2004.10.012 · DOI
  3. 10.1111/evj.12385 · doi:10.1111/evj.12385
  4. 10.2746/042516408X343000 · DOI
  5. 10.1136/vr.158.25.852 · DOI
  6. 10.1111/j.2042-3306.1996.tb01592.x · doi:10.1111/j.2042-3306.1996.tb01592.x
  7. 10.3390/ani12213053 · doi:10.3390/ani12213053
  8. 10.1016/j.jbiomech.2015.06.019 · DOI
  9. 10.2746/0425164044848244 · doi:10.2746/0425164044848244
  10. 10.1016/j.tvjl.2018.01.006 · DOI
  11. 10.1016/j.jbiomech.2020.110146 · DOI
  12. 10.1016/j.cveq.2007.04.008 · doi:10.1016/j.cveq.2007.04.008
  13. 10.2460/ajvr.72.9.1156 · doi:10.2460/ajvr.72.9.1156
  14. 10.1242/jeb.01658 · DOI · Paper page
  15. 10.1111/evj.13545 · DOI
  16. 10.7717/peerj.783 · DOI
  17. 10.1016/j.bspc.2019.101674 · doi:10.1016/j.bspc.2019.101674
  18. 10.2460/ajvr.2004.65.665 · DOI
  19. 10.7717/peerj.13517 · DOI
  20. 10.1038/s41592-018-0234-5 · DOI · Paper page
  21. 10.1038/s41593-018-0209-y · DOI · Paper page
  22. CaoZ HidalgoG SimonT WeiS‐E SheikhY.OpenPose: Realtime multi‐person 2D pose estimation using part affinity fields.2018. arXiv.org [cited 2024 Oct 3]. Available from:https://arxiv.org/abs/1812.08008v2 · arXiv
  23. 10.1145/3412841.3441973 · DOI
  24. 10.3390/ani13030390 · DOI
  25. Gan Z, 2016, Passive dynamics explain quadrupedal walking, trotting, and tölting, J Comput Nonlinear Dyn, 11
  26. Butterworth S, 1930, On the theory of filter amplifiers, Wirel Eng, 7, 536
  27. Daniel WW, 2018, Biostatistics: a foundation for analysis in the health sciences
  28. 10.1016/j.media.2024.103141 · doi:10.1016/j.media.2024.103141
  29. 10.3390/s18030850 · DOI
  30. 10.1111/evj.14089 · doi:10.1111/evj.14089
  31. 10.7717/peerj.12995 · DOI · Paper page

Metadata

Authors
Key, K., Berg, K., Kirkegaard, J., Andresen, K. R., & Skov Hansen, S.
Venue
Equine Veterinary Journal
Publisher
Wiley
Published
2025-11-04
Volume
58
Issue
5
Pages
1467-1481
ISSN
  • 0425-1644
  • 2042-3306
Cited by
2
References
3
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.