A s prayable luminescent pH sensor and its use for wound imaging in vivo
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Non‐invasive luminescence imaging is of great interest for studying biological parameters in wound healing, tumors and other biomedical fields. Recently, we developed the first method for 2 D luminescence imaging of p H in vivo on humans, and a novel method for one‐stop‐shop visualization of oxygen and p H using the RGB read‐out of digital cameras. Both methods make use of semitransparent sensor foils. Here, we describe a sprayable ratiometric luminescent p H sensor, which combines properties of both these methods. Additionally, a major advantage is that the sensor spray is applicable to very uneven tissue surfaces due to its consistency. A digital RGB image of the spray on tissue is taken. The signal of the p H indicator (fluorescein isothiocyanate) is stored in the green channel (G), while that of the reference dye [ruthenium(II)‐tris‐(4,7‐diphenyl‐1,10‐phenanthroline)] is stored in the red channel (R). Images are processed by rationing luminescence intensities (G/R) to result in pseudocolor pH maps of tissues, e.g. wounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemistry and biology of reactive oxygen species in signaling or stress responses
Dickinson, B. C., & Chang, C. J. (2011) · Nature Chemical Biology · doi:10.1038/nchembio.607 · Cited by 1,821
A tissue-scale gradient of hydrogen peroxide mediates rapid wound detection in zebrafish
Niethammer, P., Grabher, C., Look, A. T., & Mitchison, T. J. (2009) · Nature · doi:10.1038/nature08119 · Cited by 1,541
Bickers (2006) · doi:10.1016/j.jaad.2006.05.048 · Cited by 741
The impact of the pH value on skin integrity and cutaneous wound healing
Schreml, S., Szeimies, R., Karrer, S., Heinlin, J., Landthaler, M., & Babilas, P. (2010) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/j.1468-3083.2009.03413.x · Cited by 279
Self-citationBumke, M. A., Neri, D., & Elia, G. (2003) · PROTEOMICS · doi:10.1002/pmic.200300395 · Cited by 45
Cited by
An overview of nanoparticles commonly used in fluorescent bioimaging
Wolfbeis, O. S. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00392f · Cited by 1,631
Self-citationOptical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Self-citationWencel, D., Abel, T., & McDonagh, C. (2014) · Analytical Chemistry · doi:10.1021/ac4035168 · Cited by 541
Recent Advances in Wearable Sensors for Health Monitoring
Rodgers, M. M., Pai, V. M., & Conroy, R. S. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2357257 · Cited by 325
“Spray-on sensors [33], and self-healing polymers [34] are two examples”
BackgroundSmart Wound Dressings for Diabetic Chronic Wounds
Gianino, E., Miller, C., & Gilmore, J. (2018) · Bioengineering · doi:10.3390/bioengineering5030051 · Cited by 206
“In a split skin donor site, pH decreased prior to wound closure [119].”
BackgroundMethodInfluential
Metadata
- Authors
- Schreml, S., Meier, R. J., Weiß, K. T., Cattani, J., Flittner, D., Gehmert, S., Wolfbeis, O. S., Landthaler, M., & Babilas, P.
- Venue
- Experimental Dermatology
- Publisher
- Wiley
- Published
- 2012-11-22
- Volume
- 21
- Issue
- 12
- Pages
- 951-953
- ISSN
- 0906-6705 (ISSN-L)
- 1600-0625
- OpenAlex
- W2021234777
- Cited by
- 58
- References
- 5
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A s prayable luminescent pH sensor and its use for wound imaging in vivo. https://app.cochat.ai/papers/10.1111/exd.12042
- The paper
- Schreml, S., Meier, R. J., Weiß, K. T., Cattani, J., Flittner, D., Gehmert, S., Wolfbeis, O. S., Landthaler, M., & Babilas, P. (2012). A s prayable luminescent pH sensor and its use for wound imaging in vivo. Experimental Dermatology. https://doi.org/10.1111/exd.12042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.