Cited by 4Per- and polyfluoroalkyl substances researchToxic Organic Pollutants ImpactPesticide and Herbicide Environmental Studies

Assessment of Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS) Mass Flux and Distributions in a Lake System Using Sediment Bed Passive Flux Meters and Ceramic Dosimeters

Open access
Haluska, Alexander, Meder, Andreas, Susset, Bernd, Röhler, Klaus, Seelig, Renate, Ershadi, Amirhossein, Cho, Jay, Annable, Michael D. +1 more·2024·Groundwater Monitoring & Remediation

Abstract

Per‐ and polyfluoroalkyl substances (PFAS) are persistent in the environment due to their chemical stability and can spread quickly in a lake system due to mixing. Passive samplers allow for time‐weighted average concentration monitoring and the ability to detect low concentrations, which are difficult to measure with conventional grab sampling. This study demonstrates the feasibility of deploying both ceramic dosimeters and Sediment Bed Passive Flux Meters (SBPFMs) to assess time integrated PFAS concentrations and fluxes, respectively, at a historically contaminated PFAS lake near Baden‐Baden, Germany. Long‐term surface water grab samples resulted in the detection of PFBA, PFPeA, PFHxA, PFHpA, PFOA, PFNA, PFDA, PFBS, PFHxS, and PFOS at a total concentration of approximately 1 μg/L. Dosimeters were deployed for 66 and 126 d, resulting in detected concentrations ranging from approximately 250 to 380 ng/L and 120 to 460 ng/L, respectively. The 66 d deployment resulted in the detection of PFPeA, PFHxA, PFHpA, and PFOA, whereas the 126 d deployment additionally detected PFBA, PFNA, PFDA, PFUnDA, PFDoDA, PFTeDA, PFBS, PFPeS, PFOS, PFNS, and PFDS. SBPFMs resulted in the detection of PFBA, PFPeA, PFHxA, PFHpA, PFOA, PFNA, PFUnA, PFTrDA, and PFBS and the determination of a total mass discharge of 5.6 g/d into the lake. Overall, dosimeters and SBPFMs are more sensitive than grab samples at detecting PFAS at low concentrations and can be used to better understand spatial distribution of PFAS in a lake system.

Integrity signals

Registry

Crossref · 10.1111/gwmr.12665

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Haluska, A., Meder, A., Susset, B., Röhler, K., Seelig, R., Ershadi, A., Cho, J., Annable, M. D., & Grathwohl, P.
Corresponding author
Haluska, Alexander
Venue
Groundwater Monitoring & Remediation
Publisher
Wiley
Published
2024-07-15
Volume
44
Issue
4
Pages
38-52
ISSN
  • 1069-3629 (ISSN-L)
  • 1745-6592
OpenAlex
W4400655103
Cited by
4
References
0
Citations by year
2026: 1 · 2025: 2 · 2024: 1
FWCI
0.53
Type
journal article
Language
en
Open access
Locations
Groundwater Monitoring & Remediation (publishedVersion, cc-by)
Funders
  • University of Florida
  • Eberhard Karls Universität Tübingen
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Toxic Organic Pollutants Impact
  • Physical Sciences › Environmental Science › Pollution › Pesticide and Herbicide Environmental Studies
Keywords
per- and polyfluoroalkyl substances, PFAS, passive sampling, lake pollution, perfluorooctanoic acid, PFOS, PFPeA, perfluorohexanoic acid, PFHpA, perfluorobutanoic acid, PFBS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review