Very volatile organic compounds: an understudied class of indoor air pollutants
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Very volatile organic compounds (VVOCs), as categorized by the WHO, are an important subgroup of indoor pollutants and cover a wide spectrum of chemical substances. Some VVOCs are components of products commonly used indoors, some result from chemical reactions and some are reactive precursors of secondary products. Nevertheless, there is still no clear and internationally accepted definition of VVOCs. Current approaches are based on the boiling point, and the saturation vapor pressure or refer to analytical procedures. A significant problem is that many airborne VVOCs cannot be routinely analyzed by the usually applied technique of sampling on Tenax TA® followed by thermal desorption GC/MS or by DNPH-sampling/HPLC/UV. Some VVOCs are therefore often neglected in indoor-related studies. However, VVOCs are of high significance for indoor air quality assessment and there is need for their broader consideration in measurement campaigns and material emission testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Self-citationChemistry of the Upper and Lower Atmosphere
(2000) · Elsevier eBooks · doi:10.1016/b978-0-12-257060-5.x5000-x · Cited by 1,796
Handbook of Physical-Chemical Properties and Environmental Fate for Organic Chemicals
Mackay, D., Shiu, W.-Y., Shiu, W.-Y., & Lee, S. C. (2006) · CRC Press eBooks · doi:10.1201/9781420044393 · Cited by 940
Chemistry and Physiology of Los Angeles Smog
Haagen-Smit, A. J. (1952) · Industrial & Engineering Chemistry · doi:10.1021/ie50510a045 · Cited by 834
Changes in indoor pollutants since the 1950s
Weschler, C. J. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.044 · Cited by 669
Sarigiannis, D. A., Karakitsios, S. P., Gotti, A., Liakos, I. L., & Katsoyiannis, A. (2011) · Environment International · doi:10.1016/j.envint.2011.01.005 · Cited by 522
Compendium of methods for the determination of toxic organic compounds in ambient air
Riggin, R. M., Winberry, W. T., & Murphy, N. T. (1988) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 449
Wisthaler, A., & Weschler, C. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904498106 · Cited by 444
WENT, F. W. (1960) · Nature · doi:10.1038/187641a0 · Cited by 425
Duan, J., Tan, J., Yang, L., Wu, S., & Hao, J. (2008) · Atmospheric Research · doi:10.1016/j.atmosres.2007.09.004 · Cited by 397
Cited by
Assessing Human Exposure to Organic Pollutants in the Indoor Environment
Salthammer, T., Zhang, Y., Mo, J., Koch, H. M., & Weschler, C. J. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201711023 · Cited by 206
Self-citationThe role of microextraction techniques in occupational exposure assessment. A review
Jalili, V., Barkhordari, A., & Norouzian Baghani, A. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.104086 · Cited by 35
Metadata
- Authors
- Salthammer, T.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2014-12-24
- Volume
- 26
- Issue
- 1
- Pages
- 25-38
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2089921405
- Cited by
- 165
- References
- 60
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Very volatile organic compounds: an understudied class of indoor air pollutants. https://app.cochat.ai/papers/10.1111/ina.12173
- The paper
- Salthammer, T. (2016). Very volatile organic compounds: an understudied class of indoor air pollutants. Indoor Air. https://doi.org/10.1111/ina.12173
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.