Fine and ultrafine particle removal efficiency of new residential HVAC filters
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Particle air filters used in central residential forced-air systems are most commonly evaluated for their size-resolved removal efficiency for particles 0.3-10 µm using laboratory tests. Little information exists on the removal efficiency of commercially available residential filters for particles smaller than 0.3 µm or for integral measures of mass-based aerosol concentrations (eg, PM2.5) or total number concentrations (eg, ultrafine particles, or UFPs) that are commonly used in regulatory monitoring and building measurements. Here, we measure the size-resolved removal efficiency of 50 new commercially available residential HVAC filters installed in a recirculating central air-handling unit in an unoccupied apartment unit using alternating upstream/downstream measurements with incense and NaCl as particle sources. Size-resolved removal efficiencies are then used to estimate integral measures of PM2.5 and total UFP removal efficiency for the filters assuming they are challenged by 201 residential indoor particle size distributions (PSDs) gathered from the literature. Total UFP and PM2.5 removal efficiencies generally increased with manufacturer-reported filter ratings and with filter thickness, albeit with numerous exceptions. PM2.5 removal efficiencies were more influenced by the assumption for indoor PSD than total UFP removal efficiencies. Filters with the same ratings but from different manufacturers often had different removal efficiencies for PM2.5 and total UFPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translocation of inhaled ultrafine particles to the brain
Oberdörster, G., Sharp, Z., Atudorei, V., Elder, A., Gelein, R., Kreyling, W., & Cox, C. (2004) · Inhalation Toxicology · doi:10.1080/08958370490439597 · Cited by 2,606
Burnett, R. T., Pope, C. A., Ezzati, M., Olives, C., Lim, S. S., Mehta, S., Shin, H. H., Singh, G., Hubbell, B., Brauer, M., et al. (2014) · Environmental Health Perspectives · doi:10.1289/ehp.1307049 · Cited by 1,901
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Individual dose and exposure of Italian children to ultrafine particles
Buonanno, G., Marini, S., Morawska, L., & Fuoco, F. C. (2012) · Science of The Total Environment · doi:10.1016/j.scitotenv.2012.08.074 · Cited by 116
Cited by
Miller, S. L., Nazaroff, W. W., Jimenez, J. L., Boerstra, A., Buonanno, G., Dancer, S. J., Kurnitski, J., Marr, L. C., Morawska, L., & Noakes, C. (2021) · Indoor Air · doi:10.1111/ina.12751 · Cited by 734
Health Effects of Wildfire Smoke in Children and Public Health Tools: A Narrative Review
Holm, S. M., Miller, M. D., & Balmes, J. R. (2021) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-020-00267-4 · Cited by 246
“Because ultrafine particles (a major component of wildfire smoke) are filtered the least well [139], more would be expected to pass through the filter during wildfire smoke events compared to non-wildfire times.”
Composition of Particulate Matter During a Wildfire Smoke Episode in an Urban Area
Sparks, T. L., & Wagner, J. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2021.1895429 · Cited by 81
Metadata
- Authors
- Fazli, T., Zeng, Y., & Stephens, B.
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2019-06-03
- Volume
- 29
- Issue
- 4
- Pages
- 656-669
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2944653130
- Cited by
- 52
- References
- 4
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.