Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 339

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

High‐frequency Oscillations after Status Epilepticus: Epileptogenesis and Seizure Genesis

Open access
Bragin, Anatol, Wilson, Charles L., Almajano, Joyel, Mody, Istvan, Engel, Jerome·2004·Epilepsia

Abstract

Summary: Purpose: To investigate the temporal relation between high‐frequency oscillations (HFOs) in the dentate gyrus and recurrent spontaneous seizures after intrahippocampal kainite‐induced status epilepticus. Methods: Recording microelectrodes were implanted bilaterally in different regions of hippocampus and entorhinal cortex. A guide cannula for microinjection of kainic acid (KA) was implanted above the right posterior CA3 area of hippocampus. After recording baseline electrical activity, KA (0.4 μg/0.2 μl) was injected. Beginning on the next day, electrographic activity was recorded with video monitoring for seizures every day for 8 h/day for ≥30 days. Results: Of the 26 rats studied, 19 revealed the appearance of sharp‐wave activity and HFOs in the frequency range of 80 to 500 Hz in the dentate gyrus ipsilateral to the KA injection. In the remaining seven rats, no appreciable activity was noted in this frequency range. In some rats with recurrent seizures, HFOs were in the ripple frequency range (100–200 Hz); in others, HFOs were in the fast ripple frequency range (200–500 Hz), or a mixture of both oscillation frequencies was found. The time of detection of the first HFOs after status epilepticus varied between 1 and 30 days, with a mean of 6.3 ± 2.0 (SEM). Of the 19 rats in which HFO activity appeared, all later developed recurrent spontaneous seizures, whereas none of the rats without HFOs developed seizures. The sooner HFO activity was detected after status epilepticus, the sooner the first spontaneous seizure occurred. A significant inverse relation was found between the time to the first HFO detection and the subsequent rate of spontaneous seizures. Conclusions: A strong correlation was found between a decreased time to detection of HFOs and an increased rate of spontaneous seizures, as well as with a decrease in the duration of the latent period between KA injection and the detection of spontaneous seizures. Two types of HFOs were found after KA injection, one in the frequency range of 100 to 200 Hz, and the other, in the frequency range of 200 to 500 Hz, and both should be considered pathological, suggesting that both are epileptogenic.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.0013-9580.2004.17004.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 339

Metadata

Authors
Bragin, A., Wilson, C. L., Almajano, J., Mody, I., & Engel, J.
Venue
Epilepsia
Publisher
Wiley
Published
2004-08-24
Volume
45
Issue
9
Pages
1017-1023
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W2023249920
Cited by
339
References
5
FWCI
6.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐frequency Oscillations after Status Epilepticus: Epileptogenesis and Seizure Genesis. https://app.cochat.ai/papers/10.1111/j.0013-9580.2004.17004.x
The paper
Bragin, A., Wilson, C. L., Almajano, J., Mody, I., & Engel, J. (2004). High‐frequency Oscillations after Status Epilepticus: Epileptogenesis and Seizure Genesis. Epilepsia. https://doi.org/10.1111/j.0013-9580.2004.17004.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.