Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 349

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Three‐dimensional analysis of porous BaTiO3 ceramics using FIB nanotomography

HOLZER, L., INDUTNYI, F., GASSER, PH., MÜNCH, B., WEGMANN, M.·2004·Journal of Microscopy

Abstract

Summary: Three‐dimensional (3D) data represent the basis for reliable quantification of complex microstructures. Therefore, the development of high‐resolution tomography techniques is of major importance for many materials science disciplines. In this paper, we present a novel serial sectioning procedure for 3D analysis using a dual‐beam FIB (focused ion beam). A very narrow and reproducible spacing between the individual imaging planes is achieved by using drift correction algorithms in the automated slicing procedure. The spacing between the planes is nearly of the same magnitude as the pixel resolution on scanning electron microscopy images. Consequently, the acquired stack of images can be transformed directly into a 3D data volume with a voxel resolution of 6 × 7 × 17 nm. To demonstrate the capabilities of FIB nanotomography, a BaTiO 3 ceramic with a high volume fraction of fine porosity was investigated using the method as a basis for computational microstructure analysis and the results compared with conventional physical measurements. Significant differences between the particle size distributions as measured by nanotomography and laser granulometry indicate that the latter analysis is skewed by particle agglomeration/aggregation in the raw powder and by uncertainties related to calculation assumptions. Significant differences are also observed between the results from mercury intrusion porosimetry (MIP) and 3D pore space analysis. There is strong evidence that the ink‐bottle effect leads to an overestimation of the frequency of small pores in MIP. FIB nanotomography thus reveals quantitative information of structural features smaller than 100 nm in size which cannot be acquired easily by other methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.0022-2720.2004.01397.x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 349

Metadata

Authors
HOLZER, L., INDUTNYI, F., GASSER, P., MÜNCH, B., & WEGMANN, M.
Venue
Journal of Microscopy
Publisher
Wiley
Published
2004-09-15
Volume
216
Issue
1
Pages
84-95
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W2123634595
Cited by
349
References
13
FWCI
7.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three‐dimensional analysis of porous BaTiO3 ceramics using FIB nanotomography. https://app.cochat.ai/papers/10.1111/j.0022-2720.2004.01397.x
The paper
HOLZER, L., INDUTNYI, F., GASSER, P., MÜNCH, B., & WEGMANN, M. (2004). Three‐dimensional analysis of porous BaTiO3 ceramics using FIB nanotomography. Journal of Microscopy. https://doi.org/10.1111/j.0022-2720.2004.01397.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.