The DOI matches its Crossref record.
Microvascular perfusion upon exchange transfusion with stored red blood cells in normovolemic anemic conditions
Abstract
BACKGROUND: Transfusions are intended to augment oxygen‐carrying capacity. The ability of fresh and stored red blood cells (RBCs) to maintain microvascular perfusion and oxygen delivery to the tissue has not been directly measured. STUDY DESIGN AND METHODS: Microvascular responses to exchange transfusion with fresh and stored RBCs after acute isovolemic hemodilution with a plasma expander were investigated with the hamster window chamber model. In‐vivo functional capillary density (FCD), blood flow, and high‐resolution oxygen distribution in microvascular networks were measured by noninvasive methods. RESULTS: Exchange transfusion with an RBC suspension after a 60 percent isovolemic hemodilution with dextran 70 (6% MW = 70 kDa) resulted in a hematocrit of 18 percent (5.6 ± 0.2 g/dL hemoglobin [Hb]). All other systemic variables were unchanged. Stored RBCs (28 days in citrate‐phosphate‐dextrose‐adenine‐1) resuspended in fresh frozen plasma matched to the Hct and Hb concentration were exchange transfused until 25 percent of the circulating RBCs were stored RBCs. Stored RBCs reduced microvascular flow and FCD by 63 and 54 percent, respectively, of the level achieved when fresh RBCs were exchange transfused. Microvascular oxygen extraction by the stored RBC was 54 percent lower than that of the fresh RBCs. The tissue oxygen levels were 3.5 and 14.4 mmHg for the stored and fresh RBCs, respectively. CONCLUSION: Circulation of stored RBCs in a hemodiluted animal resulted in significantly malperfused and underoxygenated microvasculature that was not detectable at the systemic level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Murphy, G. J., Reeves, B. C., Rogers, C. A., Rizvi, S. I. A., Culliford, L., & Angelini, G. D. (2007) · Circulation · doi:10.1161/circulationaha.107.698977 · Cited by 1,371
Ferraris, V. A., Ferraris, S. P., Saha, S. P., Hessel, E. A., Haan, C. K., Royston, B. D., Bridges, C. R., Higgins, R. S. D., Despotis, G., Brown, J. R., et al. (2007) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.02.099 · Cited by 964
Evolution of adverse changes in stored RBCs
Bennett-Guerrero, E., Veldman, T. H., Doctor, A., Telen, M. J., Ortel, T. L., Reid, T. S., Mulherin, M. A., Zhu, H., Buck, R. D., Califf, R. M., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708160104 · Cited by 622
Clinical consequences of red cell storage in the critically ill
Tinmouth, A., Fergusson, D., Yee, I. C., Hébert, P. C., & ABLE Investigators and the Canadian Critical Care Trials Group (2006) · Transfusion · doi:10.1111/j.1537-2995.2006.01026.x · Cited by 577
Clinical practice guideline: Red blood cell transfusion in adult trauma and critical care*
Napolitano, L. M., Kurek, S., Luchette, F. A., Corwin, H. L., Barie, P. S., Tisherman, S. A., Hebert, P. C., Anderson, G. L., Bard, M. R., Bromberg, W., et al. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b39f1b · Cited by 551
Metadata
- Authors
- Tsai, A. G., Cabrales, P., & Intaglietta, M.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 2004-10-22
- Volume
- 44
- Issue
- 11
- Pages
- 1626-1634
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W2052787700
- Cited by
- 188
- References
- 0
- FWCI
- 8.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microvascular perfusion upon exchange transfusion with stored red blood cells in normovolemic anemic conditions. https://app.cochat.ai/papers/10.1111/j.0041-1132.2004.04128.x
- The paper
- Tsai, A. G., Cabrales, P., & Intaglietta, M. (2004). Microvascular perfusion upon exchange transfusion with stored red blood cells in normovolemic anemic conditions. Transfusion. https://doi.org/10.1111/j.0041-1132.2004.04128.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.