Impact of endoscopist withdrawal speed on polyp yield: implications for optimal colonoscopy withdrawal time
Open accessAbstract
Summary: Background: In 2002, a U.S. Multi‐Society Task Force on Colorectal Cancer recommended that the withdrawal phase for colonoscopy should average at least 6–10 min. This was based on 10 consecutive colonoscopies by two endoscopists with different adenoma miss rates. Aims: To characterize the relationship between endoscopist withdrawal time and polyp detection at colonoscopy, and to determine the withdrawal time that corresponds to the median polyp detection rate. Design: Procedural data from out‐patient colonoscopies performed at the Mayo Clinic, Rochester during 2003 were reviewed. Endoscopists were characterized by their mean withdrawal time for a negative procedure and individual polyp detection rate. Results: A total of 10 955 colonoscopies performed by 43 endoscopists were analysed. Median withdrawal time was 6.3 min (range: 4.2–11.9); polyp detection rate was 44.0% (all polyps), 29.8% (≤5 mm), 5.9% (6–9 mm), 6.7% (10–19 mm), 2.1% (≥20 mm). Longer withdrawal time was associated with higher polyp detection rate (r = 0.76; P < 0.0001); this relationship weakened for larger polyps (r = 0.19 for polyps 6–9 mm, r = 0.28 for polyps 10–19 mm, r = 0.02 for polyps ≥20 mm). Overall median polyp detection rate corresponded to a withdrawal time of 6.7 min. Conclusion: Our findings support a colonoscopy withdrawal time of at least 7 min, which correlates with higher colon polyp detection rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quality indicators for colonoscopy
Rex, D. K., Schoenfeld, P. S., Cohen, J., Pike, I. M., Adler, D. G., Fennerty, M. B., Lieb, J. G., Park, W. G., Rizk, M. K., Sawhney, M. S., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.07.058 · Cited by 1,764
Quality Indicators for Colonoscopy
Rex, D. K., Schoenfeld, P. S., Cohen, J., Pike, I. M., Adler, D. G., Fennerty, B. M., Lieb, J. G., Park, W. G., Rizk, M. K., Sawhney, M. S., et al. (2015) · American Journal of Gastroenterology · doi:10.1038/ajg.2014.385 · Cited by 1,401
Cairns, S. R., Scholefield, J. H., Steele, R. J., Dunlop, M. G., Thomas, H. J. W., Evans, G. D., Eaden, J. A., Rutter, M. D., Atkin, W. P., Saunders, B. P., et al. (2010) · Gut · doi:10.1136/gut.2009.179804 · Cited by 1,141
Quality Indicators for Colonoscopy
Rex, D. K., Petrini, J. L., Baron, T. H., Chak, A., Cohen, J., Deal, S. E., Hoffman, B., Jacobson, B. C., Mergener, K., Petersen, B. T., et al. (2006) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2006.00673.x · Cited by 845
Self-citationRex, D. K., & Helbig, C. C. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.04.029 · Cited by 386
Metadata
- Authors
- SIMMONS, D. T., HAREWOOD, G. C., BARON, T. H., PETERSEN, B. T., WANG, K. K., BOYD‐ENDERS, F., & OTT, B. J.
- Venue
- Alimentary Pharmacology & Therapeutics
- Publisher
- Wiley
- Published
- 2006-08-31
- Volume
- 24
- Issue
- 6
- Pages
- 965-971
- ISSN
- 0269-2813 (ISSN-L)
- 1365-2036
- OpenAlex
- W2072882279
- Cited by
- 220
- References
- 0
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of endoscopist withdrawal speed on polyp yield: implications for optimal colonoscopy withdrawal time. https://app.cochat.ai/papers/10.1111/j.1365-2036.2006.03080.x
- The paper
- SIMMONS, D. T., HAREWOOD, G. C., BARON, T. H., PETERSEN, B. T., WANG, K. K., BOYD‐ENDERS, F., & OTT, B. J. (2006). Impact of endoscopist withdrawal speed on polyp yield: implications for optimal colonoscopy withdrawal time. Alimentary Pharmacology & Therapeutics. https://doi.org/10.1111/j.1365-2036.2006.03080.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.