The DOI matches its Crossref record.
Safety and efficacy of the laryngeal mask airway A prospective survey of 1400 children
Abstract
Summary: A survey of laryngeal mask airway usage in 1400 infants and children by ten trainee anaesthetists was undertaken to provide information about insertion and complication rates using the standard insertion technique and a limited range of standardised anaesthetic techniques. Placement was successful in 90% (1258/1400) at the first attempt, 8% (112/1400) at the second attempt and 2% (29/1400) required an alternative technique of insertion. One patient vomited during insertion and the procedure was abandoned, hut aspiration did not occur. The overall problem rate was 11.5% and there were significantly more problems during induction of anaesthesia (p < 0.02). Oxygen saturation decreased below 90% briefly on 23 occasions (1.7%). The incidence of problems was unrelated to the mode of ventilation, or whether isoflurane or total intravenous anaesthesia with propofol was used for maintenance. Most problems came with use of the size 1 laryngeal mask (p < 0.001). The subspecialty with the highest problem rate was ear, nose and throat surgery (p < 0.001). There was a significant decrease in problems with increasing experience (p < 0.001). There was no major morbidity associated with use of the device. We conclude that the laryngeal mask provides a safe and effective form of airway management for infants and children in the hands of supervised anaesthesia trainees both for spontaneous and controlled ventilation using either isoflurane or total intravenous anaesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kleinman, M. E., Chameides, L., Schexnayder, S. M., Samson, R. A., Hazinski, M. F., Atkins, D. L., Berg, M. D., de Caen, A. R., Fink, E. L., Freid, E. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971101 · Cited by 1,949
Berg, M. D., Schexnayder, S. M., Chameides, L., Terry, M., Donoghue, A., Hickey, R. W., Berg, R. A., Sutton, R. M., & Hazinski, M. F. (2010) · Pediatrics · doi:10.1542/peds.2010-2972c · Cited by 398
Brull, S. J., & Murphy, G. S. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181da8312 · Cited by 288
Kleinman, M. E., de Caen, A. R., Chameides, L., Atkins, D. L., Berg, R. A., Berg, M. D., Bhanji, F., Biarent, D., Bingham, R., Coovadia, A. H., et al. (2010) · Pediatrics · doi:10.1542/peds.2010-2972a · Cited by 86
Metadata
- Authors
- Lopez‐Gil, M., Brimacombe, J., & Alvarez, M.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 1996-10
- Volume
- 51
- Issue
- 10
- Pages
- 969-972
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2061327760
- Cited by
- 202
- References
- 0
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety and efficacy of the laryngeal mask airway A prospective survey of 1400 children. https://app.cochat.ai/papers/10.1111/j.1365-2044.1996.tb14968.x
- The paper
- Lopez‐Gil, M., Brimacombe, J., & Alvarez, M. (1996). Safety and efficacy of the laryngeal mask airway A prospective survey of 1400 children. Anaesthesia. https://doi.org/10.1111/j.1365-2044.1996.tb14968.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.