A comparison of the Invos 3100 and the Critikon 2020 near‐infrared spectrophotometers as monitors of cerebral oxygenation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Assessment of cerebral oxygenation using near‐infrared spectroscopy in intensive care is increasing. We compared the ability of the Invos 3100 and the Critikon 2020 monitors to produce stable and consistent readings of regional cerebral oxygen saturation in resting volunteers. Failure to obtain any stable reading with the Critikon occurred in eight out of 18 subjects (44.4%) and with the Invos in three out of 15 subjects (20%). The Critikon showed a significantly higher failure rate in male subjects (p = 0.0011). Differences in recorded values of cerebral oxygen saturation (Critikon − Invos) ranged from −4.7% to 12.6% and were significantly related to the average saturation level (p < 0.0001). The within‐monitor variability was significantly higher for the Invos (p = 0.0124). Neither monitor is able to give stable and consistent readings over time, particularly in male subjects. The unacceptably high failure rate of the recently introduced Critikon 2020 will limit or prevent its clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Thavasothy, M., Broadhead, M., Elwell, C., Peters, M., & Smith, M. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02826.x · Cited by 165
Hyttel-Sorensen, S., Sorensen, L. C., Riera, J., & Greisen, G. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.003047 · Cited by 92
KOMIYAMA, T., QUARESIMA, V., SHIGEMATSU, H., & FERRARI, M. (2001) · Clinical Science · doi:10.1042/cs1010715 · Cited by 31
Metadata
- Authors
- McKeating, E. G., Monjardino, J. R., Signorini, D. F., Souter, M. J., & Andrews, P. J. D.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 1997-02
- Volume
- 52
- Issue
- 2
- Pages
- 136-140
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2077734171
- Cited by
- 36
- References
- 1
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of the Invos 3100 and the Critikon 2020 near‐infrared spectrophotometers as monitors of cerebral oxygenation. https://app.cochat.ai/papers/10.1111/j.1365-2044.1997.18-az015.x
- The paper
- McKeating, E. G., Monjardino, J. R., Signorini, D. F., Souter, M. J., & Andrews, P. J. D. (1997). A comparison of the Invos 3100 and the Critikon 2020 near‐infrared spectrophotometers as monitors of cerebral oxygenation. Anaesthesia. https://doi.org/10.1111/j.1365-2044.1997.18-az015.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.