Cited by 107

The DOI matches its Crossref record.

Sources of variability in nicotine and cotinine levels with use of nicotine nasal spray, transdermal nicotine, and cigarette smoking

Benowitz, N.L., Zevin, S., Jacob, P.·1997·British Journal of Clinical Pharmacology

Abstract

Aims Nicotine nasal spray and transdermal nicotine are effective aids to smoking cessation, and are being evaluated for treatment of other medical diseases. Wide variation in levels of nicotine and its metabolite, cotinine, have been observed with such therapies. This study aimed primarily to assess sources of individual variability in nicotine and metabolite plasma levels from these dosing systems and from cigarette smoking. Methods Twelve cigarette smokers, studied on a clinical research ward, received four treatments of 5 days duration each, including (1) cigarette smoking, 16 cigarettes/day; (2) transdermal nicotine, 15 mg/day; (3) nicotine nasal spray, 24–1 mg doses/day; (4) placebo nicotine nasal spray, 24 doses/day. On a different occasion, the disposition kinetics of nicotine and cotinine were determined via infusion of deuterium‐labeled nicotine and cotinine. Plasma levels of nicotine, cotinine, and 3′‐hydroxycotinine and daily intake of nicotine during various treatments were examined, as well as pharmacokinetic factors that determined plasma nicotine and cotinine levels. Results There was considerable individual variation in plasma nicotine and cotinine levels and in the daily dose of nicotine absorbed from various delivery systems, with most variability with nicotine nasal spray (fivefold) and least for transdermal nicotine (two‐to threefold). Plasma nicotine levels were determined most strongly by nicotine clearance. Cotinine levels were determined most strongly by dose of nicotine and, to a lesser extent, the clearance of cotinine and fractional conversion of nicotine to cotinine. Conclusions Plasma levels of nicotine and cotinine produced by nicotine therapies are highly variable, due to both wide variability in individual pharmacokinetics and in dose delivery from the products. To compensate for individual differences in clearance, individualization of nicotine dosing based on therapeutic drug monitoring with comparison to nicotine or cotinine levels during cigarette smoking prior to treatment may be necessary to optimize nicotine therapy. This study also validates a recently proposed method for estimating absolute bioavailability of a drug using drug and metabolite pharmacokinetic data, and presents novel data on plasma levels of the metabolite trans‐3′‐hydroxycotinine in people.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2125.1997.00566.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 6

  1. Caldwell WS, Greene JM, Byrd GD, Chang KM, Uhrig MS, Eur J Clin Pharmacol, 1997; in press. deBethizy JD. Characterization of the glucuronide conjugate 21 Benowitz NL, Jacob P, III, Kozlowski L, Yu L. Influence of of cotinine: A previously unidentified major metabolite of smoking fewer cigarettes on exposure to tar, nicotine, and nicotine in smokers' urine. Chem Res Toxicol 1992; 5: carbon monoxide exposure. N Engl J Med 1986; 314: 280-285. 1310-1313.
  2. Dale LC, Hurt RD, Offord KP, Lawson GM, Croghan IT, 22 Benowitz NL. Nicotine replacement therapy. What has been Schroeder DR. High-dose nicotine patch therapy. Percentage accomplished-can we do better? Drugs 1993; 45: 157-170. of replacement and smoking cessation. JAMA 1995; 274: 23
  3. Neurath GB, Dunger M, Orth D, Pein FG. Trans-3∞- 1353-1358. hydroxycotinine as a main metabolite in urine of smokers. Int 29 Sachs DP, Benowitz NL, Bostrum AG, Hansen MD. Percent Arch Occup Environ Hlth 1987; 59: 199-201. serum replacement and success of nicotine patch therapy. Am 24
  4. Jacob P, III, Benowitz NL, Shulgin AT. Recent studies of J Resp Crit Care Med 1995; 151: A688. nicotine metabolism in humans. Pharmacol Biochem Behav 30
  5. Henningfield JE, Stapleton JM, Benowitz NL, Grayson RF, 1988; 41: 474-479. London ED. Higher levels of nicotine in arterial than in 25
  6. Byrd GD, Chang K, Greene JM, deBethizy JD. Evidence for venous blood after cigarette smoking. Drug Alc Depend 1993; urinary excretion of glucuronide conjugates of nicotine, 33: 23-29. cotinine, and trans-3∞-hydroxycotinine in smokers. Drug Metab Dispos 1992; 20: 192-197. ( Received 3 June 1996, accepted 20 November 1996)

Cited by

Sorted by citations

Metadata

Authors
Benowitz, N. L., Zevin, S., & Jacob, P.
Venue
British Journal of Clinical Pharmacology
Publisher
Wiley
Published
1997-03
Volume
43
Issue
3
Pages
259-267
ISSN
  • 0306-5251
  • 1365-2125
Cited by
107
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review