CoChat

The kinetics of 111Indium distribution following injection of 111Indium labelled autologous granulocytes in man

Saverymuttu, S. H., Peters, A. M., Keshavarzian, A., Reavy, H. J., Lavender, J. P. · 1985 · British Journal of Haematology
Cited by 126

The DOI matches its Crossref record.

Abstract

S ummary. The kinetics of human autologous granulocytes, separated and labelled with 111 In without isolation from plasma, have been studied in subjects with and without sepsis with the aim of identifying the fate and sites of destruction of granulocytes in man. In subjects without inflammatory disease, 111 In granulocyte recovery in faeces, urine and saliva over 4 d was less than 1% of the dose, so that the activity visualized by the gamma camera represented almost 100% of the dose. On images taken at 24 and 48 h, this activity was distributed between spleen, bone marrow and liver, with foci of additional abnormal activity in subjects with inflammatory disease. Splenic activity fell between 40 min and 24 h, consistent with the presence of a splenic granulocyte pool, but remained constant after 24 h. Since granulocyte clearance from the blood was predominantly completed by 24 h, the residual splenic activity at that time reflected splenic granulocyte destruction. In patients with sepsis, the fall in splenic activity was greater than in those without, implying diversion of granulocytes from splenic destruction to tissue utilization when inflammation is present. Bone marrow activity increased between 40 min and 24 h and then remained stable. Granulocytes that were extensively manipulated in saline prior to labelling failed to localize in marrow, suggesting that visualization of the latter reflected destruction of intact, normal granulocytes. Although the changes in splenic and marrow activities terminated at 24 h, at which time granulocyte clearance from blood was at least 80% completed, plasma 111 In remained essentially unchanged between 40 min and 48 h at less than 5% of the dose, discounting it as the source of splenic and marrow activities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2141.1985.tb02882.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 126

Metadata

Authors
Saverymuttu, S. H., Peters, A. M., Keshavarzian, A., Reavy, H. J., & Lavender, J. P.
Venue
British Journal of Haematology
Publisher
Wiley
Published
1985-12
Volume
61
Issue
4
Pages
675-685
ISSN
  • 0007-1048 (ISSN-L)
  • 1365-2141
OpenAlex
W1973875131
Cited by
126
References
0
FWCI
4.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The kinetics of 111Indium distribution following injection of 111Indium labelled autologous granulocytes in man. https://app.cochat.ai/papers/10.1111/j.1365-2141.1985.tb02882.x
The paper
Saverymuttu, S. H., Peters, A. M., Keshavarzian, A., Reavy, H. J., & Lavender, J. P. (1985). The kinetics of 111Indium distribution following injection of 111Indium labelled autologous granulocytes in man. British Journal of Haematology. https://doi.org/10.1111/j.1365-2141.1985.tb02882.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.