The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Interpretation of measured red cell mass and plasma volume in adults: Expert Panel on Radionuclides of the International Council for Standardization in Haematology
Open accessAbstract
Four European centres provided height and weight data on 202 males and 204 females undergoing red cell mass (RCM) and plasma volume (PV) measurements. For these populations, the RCM and PV predictions by the various published methods were compared. It was shown clearly that predictions based solely on body weight were inappropriate, particularly because approximately half of the male and female populations could be regarded as overweight or obese. Although there was reasonable agreement in the prediction values given by the formulae based on both height and weight, it was not possible to establish which formulae could be recommended. For that reason, the published literature containing normal RCM and PV measurements were re‐examined. RCM data for 283 males and 171 females and PV data for 100 males and 67 females were included. Measurements were standardized for variables such as trapped plasma in the PCV, exclusion of buffy coat in the PCV and calculation of PV at zero time. As a result of this analysis, prediction formulae based on surface area for RCM and PV with 98/99% reference ranges have been established.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Du BOIS, D. (1916) · Archives of Internal Medicine · doi:10.1001/archinte.1916.00080130010002 · Cited by 4,342
(2016) · Time Series with Mixed Spectra · doi:10.1201/b15154-8 · Cited by 2,739
(1962) · PubMed · Cited by 2,094
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Methods for the assessment of human body composition: traditional and new
Lukaski, H. C. (1987) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/46.4.537 · Cited by 1,152
Wetherill, G. B., & Seber, G. A. F. (1977) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2345290 · Cited by 1,047
Diagnosis and classification of the polycythemias.
Berlin, N. I. (1975) · PubMed · Cited by 541
THE BODY/VENOUS HEMATOCRIT RATIO: ITS CONSTANCY OVER A WIDE HEMATOCRIT RANGE
Chaplin, H., Mollison, P. L., & Vetter, H. (1953) · Journal of Clinical Investigation · doi:10.1172/jci102859 · Cited by 393
Correction for Plasma Trapped in the Red Cell Column of the Hematocrit
CHAPLIN, H., & MOLLISON, P. L. (1952) · Blood · doi:10.1182/blood.v7.12.1227.1227 · Cited by 283
Erythrocyte Volume, Plasma Volume, and Lean Body Mass in Adult Men and Women
RETZLAFF, J. A., TAUXE, W. N., KIELY, J. M., & STROEBEL, C. F. (1969) · Blood · doi:10.1182/blood.v33.5.649.649 · Cited by 214
Cited by
Polycythemia vera: myths, mechanisms, and management
Spivak, J. L. (2002) · Blood · doi:10.1182/blood-2001-12-0349 · Cited by 463
The sex difference in haemoglobin levels in adults—mechanisms, causes, and consequences
Murphy, W. G. (2014) · Blood Reviews · doi:10.1016/j.blre.2013.12.003 · Cited by 463
Najean, Y., & Rain, J.-D. (1997) · Blood · doi:10.1182/blood.v90.9.3370 · Cited by 297
Self-citationJacob, M., Chappell, D., Hofmann-Kiefer, K., Conzen, P., Peter, K., & Rehm, M. (2007) · Der Anaesthesist · doi:10.1007/s00101-007-1235-4 · Cited by 51
Lixisenatide Reduces Chylomicron Triacylglycerol by Increased Clearance
Whyte, M. B., Shojaee-Moradie, F., Sharaf, S. E., Jackson, N. C., Fielding, B., Hovorka, R., Mendis, J., Russell-Jones, D., & Umpleby, A. M. (2019) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2018-01176 · Cited by 32
Metadata
- Authors
- Pearson, T. C., Guthrie, D. L., Simpson, J., Chinn, S., Barosi, G., Ferrant, A., Lewis, S. M., & Najean, Y.
- Venue
- British Journal of Haematology
- Publisher
- Wiley
- Published
- 1995-04
- Volume
- 89
- Issue
- 4
- Pages
- 748-756
- ISSN
- 0007-1048 (ISSN-L)
- 1365-2141
- OpenAlex
- W2066093376
- Cited by
- 321
- References
- 18
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interpretation of measured red cell mass and plasma volume in adults: Expert Panel on Radionuclides of the International Council for Standardization in Haematology. https://app.cochat.ai/papers/10.1111/j.1365-2141.1995.tb08411.x
- The paper
- Pearson, T. C., Guthrie, D. L., Simpson, J., Chinn, S., Barosi, G., Ferrant, A., Lewis, S. M., & Najean, Y. (1995). Interpretation of measured red cell mass and plasma volume in adults: Expert Panel on Radionuclides of the International Council for Standardization in Haematology. British Journal of Haematology. https://doi.org/10.1111/j.1365-2141.1995.tb08411.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.