CoChat

Radioimmunoassay of human eosinophil cationic protein (ECP) by an improved method. Establishment of normal levels in serum and turnover in vivo

PETERSON, C. G. B., ENANDER, I., NYSTRAND, J., ANDERSON, A. S., NILSSON, L., VENGE, P. · 1991 · Clinical & Experimental Allergy
Cited by 201

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Summary: A radio immunoassay was developed allowing measurement of the cytotoxic cationic ECP. The assay, which has a total incubation time of 3.5 hr, is a double antibody assay with radiolabelled ECP. covering the concentration range of 2–200 μ/l. Performance data show a detection limit of < 2 μg/1 and a cross‐reactivity with eosinophil protein X (EPX/EDN) of <0.06%. The coefficient of variation (%) within the measuring range was, within assay 4.8–10.4, and total 6.6–12.0. The assay is useful for measurement in various body fluids including serum, nasal secretions and bronchoalveolar lavage fluid, and dilution of samples prior to analysts was generally not required. Sera from 100 apparently healthy individuals revealed a geometric mean of 6.0 μg ECP/1 and a range (95%) of 2.3–15.9 μg/1. The elimination rate of ECP, t 12. in vivo was estimated to be 65 min when ECP was measured in serum. Comparisons between this assay and a method previously described showed that the new method is superior with regard to precision and assay procedure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2222.1991.tb00847.x

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 201

Metadata

Authors
PETERSON, C. G. B., ENANDER, I., NYSTRAND, J., ANDERSON, A. S., NILSSON, L., & VENGE, P.
Venue
Clinical & Experimental Allergy
Publisher
Wiley
Published
1991-09
Volume
21
Issue
5
Pages
561-567
ISSN
  • 0954-7894 (ISSN-L)
  • 1365-2222
OpenAlex
W2033148441
Cited by
201
References
21
FWCI
5.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.