The DOI matches its Crossref record.
Colorimetric quantification of erythema-a comparison of two colorimeters (Lange Micro Color and Minolta Chroma Meter CR-200) with a clinical scoring scheme and laser-Doppler flowmetry
Abstract
Erythema elicited by the local irritant sodium lauryl sulphate was studied in comparison with unexposed skin. Colour coordinates of the CIE system were recorded using two commercially available colorimeters. With both colorimeters a positive movement of the alpha-axis (toward red, P less than 0.001) and a negative movement on the L-axis (toward dark, P less than 0.01) were registered. Technical and in-vivo experimentation showed the two pieces of equipment to be accurate. However, a simple conversion factor cannot be established. Both pieces of equipment correlated positively with clinical scoring of erythema and with measurement of cutaneous blood flow by laser-Doppler flowmetry. In conclusion, the two colorimeters appeared comparable. Colorimetry by the CIE system, which takes into account the non-linear colour perception of the human eye, was found useful with potential value in both experimental and clinical dermatology. The techniques appeared suitable for routine testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fullerton, A., Fischer, T., Lahti, A., Wilhelm, K. ‐., Takiwaki, H., & Serup, J. (1996) · Contact Dermatitis · doi:10.1111/j.1600-0536.1996.tb02258.x · Cited by 406
Self-citationAshcroft, Po, L. W., Williams, & Griffiths (1999) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1999.02963.x · Cited by 287
Johansen, Skov, Volund, Andersen, & MennÉ (1998) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1998.02363.x · Cited by 96
Kuriyama, K., Shimizu, T., Horiguchi, T., Watabe, M., & Abe, Y. (2002) · Inflammation Research · doi:10.1007/pl00012416 · Cited by 30
Suh, K. ‐., Roh, H. ‐., Choi, S. ‐., Jeon, Y. ‐., Doh, K. ‐., Bae, J. ‐., & Kim, S. ‐. (2007) · Skin Research and Technology · doi:10.1111/j.1600-0846.2007.00238.x · Cited by 29
Metadata
- Authors
- SERUP, J., & AGNER, T.
- Venue
- Clinical and Experimental Dermatology
- Publisher
- Oxford University Press (OUP)
- Published
- 1990-07
- Volume
- 15
- Issue
- 4
- Pages
- 267-272
- ISSN
- 0307-6938 (ISSN-L)
- 1365-2230
- OpenAlex
- W2107048473
- Cited by
- 173
- References
- 0
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Colorimetric quantification of erythema-a comparison of two colorimeters (Lange Micro Color and Minolta Chroma Meter CR-200) with a clinical scoring scheme and laser-Doppler flowmetry. https://app.cochat.ai/papers/10.1111/j.1365-2230.1990.tb02087.x
- The paper
- SERUP, J., & AGNER, T. (1990). Colorimetric quantification of erythema-a comparison of two colorimeters (Lange Micro Color and Minolta Chroma Meter CR-200) with a clinical scoring scheme and laser-Doppler flowmetry. Clinical and Experimental Dermatology. https://doi.org/10.1111/j.1365-2230.1990.tb02087.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.