Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 655

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Thrombelastography/thromboelastometry

LUDDINGTON, R. J.·2005·Clinical and Laboratory Haematology

Abstract

The term thrombelastograph (TEG) was used to describe the trace produced from the measurement of the viscoelastic changes associated with fibrin polymerization. Recently the term rotational thromboelastometry has been applied to the output of the ROTEM instrument. Since its first description in 1948, the TEG/ROTEM has been successfully used in the near patient assessment of haemostasis. The greatest use has been the application of TEG-guided transfusion of blood components in hepatic and more widely in cardiac surgery. Recent years have seen a renewed interest in the technology with applications for both pharmaceutical monitoring and patient screening being described. The present review gives a broad overview of the developments and applications related to thrombelastography/thromboelastometry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2257.2005.00681.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 655

Metadata

Authors
LUDDINGTON, R. J.
Venue
Clinical and Laboratory Haematology
Publisher
Wiley
Published
2005-04
Volume
27
Issue
2
Pages
81-90
ISSN
  • 0141-9854 (ISSN-L)
  • 1365-2257
OpenAlex
W4232642121
Cited by
655
References
2
FWCI
17.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thrombelastography/thromboelastometry. https://app.cochat.ai/papers/10.1111/j.1365-2257.2005.00681.x
The paper
LUDDINGTON, R. J. (2005). Thrombelastography/thromboelastometry. Clinical and Laboratory Haematology. https://doi.org/10.1111/j.1365-2257.2005.00681.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.