SERUM THYROGLOBULIN CONCENTRATIONS AND 131I WHOLE BODY SCANS IN THE DIAGNOSIS OF METASTASES FROM DIFFERENTIATED THYROID CARCINOMA (AFTER THYROIDECTOMY)
The DOI matches its Crossref record.
Abstract
SUMMARY. Measurements of circulating thyroglobulin (hTg) and 131 I whole body scan were performed in 101 patients with differentiated thyroid carcinoma who had been subjected to surgical thyroidectomy and 131 I ablation of remaining thyroid tissue. All 45 patients with positive scans (i.e. functioning metastases) had elevated hTg concentrations. Of fifty‐six patients with negative scans forty‐two had undetectable or very low hTg levels and were considered to be free of metastatic thyroid tissue, whereas fourteen showed the presence of non‐functioning metastases in the clinical and/or radiological examination. In this group of patients, eleven had elevated serum hTg levels while the other three patients had detectable hTg concentrations within the normal range. These results indicate that serum hTg measurements correlate very well with scan findings and have the added advantage of detecting non‐functioning metastases which would not be detected by scanning. We concluded that measurement of serum hTg may be used together with scanning, as the first step in the follow‐up of thyroidectomized patients with differentiated thyroid carcinoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stagnaro-Green, A., Abalovich, M., Alexander, E., Azizi, F., Mestman, J., Negro, R., Nixon, A., Pearce, E. N., Soldin, O. P., Sullivan, S., et al. (2011) · Thyroid · doi:10.1089/thy.2011.0087 · Cited by 2,942
Alexander, E. K., Pearce, E. N., Brent, G. A., Brown, R. S., Chen, H., Dosiou, C., Grobman, W. A., Laurberg, P., Lazarus, J. H., Mandel, S. J., et al. (2017) · Thyroid® · doi:10.1089/thy.2016.0457 · Cited by 2,731
“In the presence of an in situ thyroid gland, serum Tg measurements are neither sensitive nor specific for thyroid cancer and can be elevated in many benign thyroid disorders (453).”
BackgroundLadenson, P. W., Braverman, L. E., Mazzaferri, E. L., Brucker-Davis, F., Cooper, D. S., Garber, J. R., Wondisford, F. E., Davies, T. F., DeGroot, L. J., Daniels, G. H., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709253371304 · Cited by 466
Pacini, F. (2002) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.87.4.1499 · Cited by 299
Self-citationPacini, F. (1992) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.74.6.1401 · Cited by 285
Self-citation
Metadata
- Authors
- PACINI, F., PINCHERA, A., GIANI, C., GRASSO, L., & BASCHIERI, L.
- Venue
- Clinical Endocrinology
- Publisher
- Wiley
- Published
- 1980-09
- Volume
- 13
- Issue
- 1
- Pages
- 107-110
- ISSN
- 0300-0664 (ISSN-L)
- 1365-2265
- OpenAlex
- W1974556474
- Cited by
- 95
- References
- 0
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SERUM THYROGLOBULIN CONCENTRATIONS AND 131I WHOLE BODY SCANS IN THE DIAGNOSIS OF METASTASES FROM DIFFERENTIATED THYROID CARCINOMA (AFTER THYROIDECTOMY). https://app.cochat.ai/papers/10.1111/j.1365-2265.1980.tb01030.x
- The paper
- PACINI, F., PINCHERA, A., GIANI, C., GRASSO, L., & BASCHIERI, L. (1980). SERUM THYROGLOBULIN CONCENTRATIONS AND 131I WHOLE BODY SCANS IN THE DIAGNOSIS OF METASTASES FROM DIFFERENTIATED THYROID CARCINOMA (AFTER THYROIDECTOMY). Clinical Endocrinology. https://doi.org/10.1111/j.1365-2265.1980.tb01030.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.