The DOI matches its Crossref record.
A RECEPTOR ASSAY FOR THE MEASUREMENT OF TSH RECEPTOR ANTIBODIES IN UNEXTRACTED SERUM
Abstract
SUMMARY: A receptor assay for TSH receptor antibodies is described in which unextracted serum, detergent solubilised TSH receptors and 125 I‐labelled TSH are used. The assay was rapid and reproducible with coefficients of inter‐assay variation of 12·3%, 2·1 and 2·6% at mean inhibition of TSH binding values of 11, 53, and 79 respectively. Assay sensitivity could be increased by reducing the volume of receptors used but some increase in the scatter of values obtained with individual normal sera was also observed. Comparison of human and porcine TSH receptor preparations indicated that porcine tissue gave greater sensitivity. Analysis of different groups of patients and normal subjects (n= 21) showed the absence of detectable TSH receptor antibody activity in 16 patients with rheumatoid arthritis, 10 with multinodular goitre and 12 with Hashimoto's disease. However the antibody was readily detectable in 28 out of 28 GRAVES' patients (treated and untreated) who were hyperthyroid at the time of assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Autoantibodies to the Thyrotropin Receptor
SMITH, B. R., McLACHLAN, S. M., & FURMANIAK, J. (1988) · Endocrine Reviews · doi:10.1210/edrv-9-1-106 · Cited by 575
Self-citationAutoimmune Polyendocrine Syndromes
Husebye, E. S., Anderson, M. S., & Kämpe, O. (2018) · New England Journal of Medicine · doi:10.1056/nejmra1713301 · Cited by 466
Laurberg, P., Wallin, G., Tallstedt, L., Abraham-Nordling, M., Lundell, G., & Tørring, O. (2008) · European Journal of Endocrinology · doi:10.1530/eje-07-0450 · Cited by 428
Clinical Utility of TSH Receptor Antibodies
Barbesino, G., & Tomer, Y. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-4309 · Cited by 237
McLachlan, S. M., & Rapoport, B. (2013) · Thyroid · doi:10.1089/thy.2012.0374 · Cited by 239
Metadata
- Authors
- SOUTHGATE, K., CREAGH, F., TEECE, M., KINGSWOOD, C., & SMITH, B. R.
- Venue
- Clinical Endocrinology
- Publisher
- Wiley
- Published
- 1984-05
- Volume
- 20
- Issue
- 5
- Pages
- 539-543
- ISSN
- 0300-0664 (ISSN-L)
- 1365-2265
- OpenAlex
- W2098576707
- Cited by
- 184
- References
- 0
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A RECEPTOR ASSAY FOR THE MEASUREMENT OF TSH RECEPTOR ANTIBODIES IN UNEXTRACTED SERUM. https://app.cochat.ai/papers/10.1111/j.1365-2265.1984.tb00102.x
- The paper
- SOUTHGATE, K., CREAGH, F., TEECE, M., KINGSWOOD, C., & SMITH, B. R. (1984). A RECEPTOR ASSAY FOR THE MEASUREMENT OF TSH RECEPTOR ANTIBODIES IN UNEXTRACTED SERUM. Clinical Endocrinology. https://doi.org/10.1111/j.1365-2265.1984.tb00102.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.