Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 172

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Variation in GH and IGF‐I assays limits the applicability of international consensus criteria to local practice

Pokrajac, A., Wark, G., Ellis, A. R., Wear, J., Wieringa, G. E., Trainer, P. J. · 2007 · Clinical Endocrinology

Abstract

Summary: Background There is increasing reliance on consensus criteria for decision making. Recent criteria state that acromegaly is excluded by a nadir GH during an oral glucose tolerance test (OGTT) of < 1 µg/l and a normal level of IGF‐I. Objective To study GH and IGF‐I assay performance close to cut‐off values for active acromegaly. Design and methods Two serum samples known to give borderline results were sent to all centres participating in the UK National External Quality Assessment Service (NEQAS). Sample A was assigned to be a nadir during an OGTT and sent for GH assessment to 104 centres. Sample B, with a clinical scenario, was sent to 23 centres that measure IGF‐I, and these centres were asked to measure IGF‐I, interpret the result and provide the source of their reference ranges (RRs). Results For sample A, the median GH was 2·6 mU/l (range 1·04–3·5 mU/l). Applying a conversion factor (CF) of 2·0 (1 µg/l = 2 mU/l), the most negatively biased method classified 10% of the values consistent with acromegaly, while the most positively biased method classified all values as consistent with the diagnosis. Applying a CF of 3·0 (1 µg/l = 3 mU/l), only 11% of results were consistent with acromegaly. For sample B, the median IGF‐I was 50·8 nmol/l (range 24·3–60·9 nmol/l). All centres used age‐related RRs. There was a 50% variation in the upper limit of the RRs between centres. Overall, 30% of the IGF‐I results were against the diagnosis. There was little agreement in the RRs quoted by centres using the same method. Conclusion Variability in assay performance, coupled with use of inappropriate CFs and RRs, undermines the applicability of international consensus criteria to local practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2265.2007.02836.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 172

Metadata

Authors
Pokrajac, A., Wark, G., Ellis, A. R., Wear, J., Wieringa, G. E., & Trainer, P. J.
Venue
Clinical Endocrinology
Publisher
Wiley
Published
2007-04-27
Volume
67
Issue
1
Pages
65-70
ISSN
  • 0300-0664 (ISSN-L)
  • 1365-2265
OpenAlex
W2034116039
Cited by
172
References
2
FWCI
10.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variation in GH and IGF‐I assays limits the applicability of international consensus criteria to local practice. https://app.cochat.ai/papers/10.1111/j.1365-2265.2007.02836.x
The paper
Pokrajac, A., Wark, G., Ellis, A. R., Wear, J., Wieringa, G. E., & Trainer, P. J. (2007). Variation in GH and IGF‐I assays limits the applicability of international consensus criteria to local practice. Clinical Endocrinology. https://doi.org/10.1111/j.1365-2265.2007.02836.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.