Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record.

Thyroglobulin measurement in fine‐needle aspirate washouts: the criteria for neck node dissection for patients with thyroid cancer

Open access
Kim, Min Jung, Kim, Eun‐Kyung, Kim, Byung Moon, Kwak, Jin Young, Lee, Eun Jig, Park, Cheong Soo, Cheong, Woong Youn, Nam, Ki Hyun · 2009 · Clinical Endocrinology

Abstract

Summary: Background Several studies report that detection of thyroglobulin (Tg) in fine‐needle aspiration (FNA) biopsy washout fluid from lymph nodes identifies recurrences/metastases of differentiated papillary thyroid cancer (DPTC) in the neck with higher sensitivity and specificity than fine‐needle aspiration cytology (FNAC). However, the diagnostic FNA‐Tg cutoff values have not yet been established. Objective To determine an appropriate diagnostic threshold value for Tg levels in FNA washout fluid in patients with neck node metastases or recurrences of DPTC. Design We performed ultrasound (US)‐guided FNAC and measured Tg levels in FNA washout fluid (FNA‐Tg). Final diagnoses were confirmed by histological examination of excised specimens or by follow‐up examinations for at least 24 months. Patients A total of 168 ultrasonographically detected lymph nodes from 168 patients with DPTC were included. Measurements In comparison with FNAC, we evaluated diagnostic sensitivity, specificity and accuracy of metastasis detection according to several predetermined threshold levels: 1, 10, 100 ng/ml, mean+2SD of node‐negative patients, and FNA‐Tg/serum‐Tg > 1. Results The diagnostic sensitivity was lowest at 77·3% for FNAC alone. The lower FNA‐Tg threshold levels showed higher diagnostic sensitivity whereas the higher FNA‐Tg showed higher specificity. In addition to the FNAC results, FNA‐Tg levels showed 95·0% sensitivity, 81·6% specificity, 92·6% in positive predictive value (PPV) and 87·0% in negative predictive value (NPV) with the threshold of FNA‐Tg level at 10 ng/ml, serum‐Tg or mean+2SD of FNA‐Tg measured in node‐negative patients. The diagnostic accuracy of FNA‐Tg was higher in neck node recurrences after thyroid surgery than in the metastasis of patients waiting for surgery. Conclusion FNA‐Tg measurement as well as FNAC should be performed either before or after surgery to evaluate neck node metastases or recurrences in patients with differentiated thyroid carcinomas. We recommend that the threshold values for FNA‐Tg levels should be > 10 ng/ml if the serum‐Tg level or the mean+2SD in node‐negative patients is not available for reference.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2265.2008.03297.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Kim, M. J., Kim, E., Kim, B. M., Kwak, J. Y., Lee, E. J., Park, C. S., Cheong, W. Y., & Nam, K. H.
Venue
Clinical Endocrinology
Publisher
Wiley
Published
2008-12-30
Volume
70
Issue
1
Pages
145-151
ISSN
  • 0300-0664 (ISSN-L)
  • 1365-2265
OpenAlex
W1989769663
Cited by
160
References
0
FWCI
7.19
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thyroglobulin measurement in fine‐needle aspirate washouts: the criteria for neck node dissection for patients with thyroid cancer. https://app.cochat.ai/papers/10.1111/j.1365-2265.2008.03297.x
The paper
Kim, M. J., Kim, E., Kim, B. M., Kwak, J. Y., Lee, E. J., Park, C. S., Cheong, W. Y., & Nam, K. H. (2009). Thyroglobulin measurement in fine‐needle aspirate washouts: the criteria for neck node dissection for patients with thyroid cancer. Clinical Endocrinology. https://doi.org/10.1111/j.1365-2265.2008.03297.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.