The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The human coronary collateral circulation
Abstract
Eur J Clin Invest 2010; 40 (5): 465–476 Background Coronary collaterals are an alternative source of blood supply to myocardium jeopardized by ischaemia. Well‐developed coronary collateral arteries in patients with coronary artery disease (CAD) mitigate myocardial infarcts and improve survival. Methods and results Collateral arteries preventing myocardial ischaemia during brief vascular occlusion are present in 1/3 of patients with CAD. Among individuals without relevant coronary stenoses, there are preformed collateral arteries preventing myocardial ischaemia in 20–25%. Collateral flow sufficient to prevent myocardial ischaemia during coronary occlusion amounts to ‡25% of the normal flow through the open vessel. Myocardial infarct size, the most important prognostic determinant after such an event, is the product of coronary artery occlusion time, area at risk for infarction and the inverse of collateral supply. Coronary collateral flow can be assessed only during vascular occlusion of the collateral‐receiving artery. The gold standard for coronary collateral assessment is the measurement of intracoronary occlusive pressure‐ or velocity‐derived collateral flow index expressing collateral as a fraction of flow during vessel patency. Approximately one of five patients with CAD cannot be revascularized by percutaneous coronary intervention or coronary artery bypass grafting. Therapeutic promotion of collateral growth is a valuable treatment strategy in those patients. Conclusions Promotion of collateral growth should aim at inducing the development of large conductive collateral arteries (i.e. arteriogenesis) and not so much the sprouting of capillary like vessels (i.e. angiogenesis). Large conductive collateral arteries appear to be effectively promoted via the activation of monocytes/macrophages by means of granulocyte‐colony stimulating factor or of augmenting coronary flow velocity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis in cancer, vascular, rheumatoid and other disease
Folkman, J. (1995) · Nature Medicine · doi:10.1038/nm0195-27 · Cited by 7,627
Cited by
Coronary Microvascular Dysfunction
Vancheri, F., Longo, G., Vancheri, S., & Henein, M. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9092880 · Cited by 321
The impact of the coronary collateral circulation on mortality: a meta-analysis
Meier, P., Hemingway, H., Lansky, A. J., Knapp, G., Pitt, B., & Seiler, C. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr308 · Cited by 294
Self-citation
Metadata
- Authors
- Seiler, C.
- Venue
- European Journal of Clinical Investigation
- Publisher
- Wiley
- Published
- 2010-04-20
- Volume
- 40
- Issue
- 5
- Pages
- 465-476
- ISSN
- 0014-2972 (ISSN-L)
- 1365-2362
- OpenAlex
- W2052398654
- Cited by
- 160
- References
- 1
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The human coronary collateral circulation. https://app.cochat.ai/papers/10.1111/j.1365-2362.2010.02282.x
- The paper
- Seiler, C. (2010). The human coronary collateral circulation. European Journal of Clinical Investigation. https://doi.org/10.1111/j.1365-2362.2010.02282.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.