Fungal and actinomycete spore aerosols measured at different humidities with an aerodynamic particle sizer
The DOI matches its Crossref record.
Abstract
T.M. MADELIN AND H.E. JOHNSON. 1992. An aerodynamic particle sizer (APS) that uses laser Doppler velocimetry was used to determine aerodynamic diameters of spores of fungal and thermophilic actinomycete species common in mouldy hay, acrosolized at different humidities and temperatures. Results were compared with those obtained from inertial impaction in a cascade impactor. The APS gave slightly smaller measurements than the cascade impactor. Both methods gave aerodynamic diameters generally slightly smaller than the average spore dimensions observed on cascade impactor slides with a microscope. The latter measurements were less than axial dimensions given in the literature. Brief passage of spores through air at 95% relative humidity (RH) and 38°C, compared with 40% RH and 20°C, caused an immediate increase in their aerodynamic diameter and the breaking of chains of spores. Cultures maintained at 75% RH and aerosolized at 98% RH similarly produced larger spore particles than those passed through dry air. These findings have implications for mould‐induced asthma and allergic alveolitis since they relate to physical behaviour of airborne spores and particle deposition sites in the lung.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Primary biological aerosol particles in the atmosphere: a review
Després, V. R., Huffman, J. A., Burrows, S. M., Hoose, C., Safatov, A. S., Buryak, G., Fröhlich-Nowoisky, J., Elbert, W., Andreae, M. O., Pöschl, U., et al. (2012) · Tellus B: Chemical and Physical Meteorology · doi:10.3402/tellusb.v64i0.15598 · Cited by 1,500
“3, p. 17; Madelin and Johnson, 1992; Reponen et al., 1998; Reponen et al., 2001), and microorganisms may sometimes be present in the atmosphere in clumps or attached to other particles (Lacey, 1991; Tong and Lighthart, 2000).”
BackgroundParticle-size distributions and seasonal diversity of allergenic and pathogenic fungi in outdoor air
Yamamoto, N., Bibby, K., Qian, J., Hospodsky, D., Rismani-Yazdi, H., Nazaroff, W. W., & Peccia, J. (2012) · The ISME Journal · doi:10.1038/ismej.2012.30 · Cited by 266
Eduard, W. (2009) · Critical Reviews in Toxicology · doi:10.3109/10408440903307333 · Cited by 251
“2 Madelin and Johnson (1992)”
Terzieva, S., Donnelly, J., Ulevicius, V, Grinshpun, S. A., Willeke, K., Stelma, G. N., & Brenner, K. P. (1996) · Applied and Environmental Microbiology · doi:10.1128/aem.62.7.2264-2272.1996 · Cited by 220
An update on pollen and fungal spore aerobiology
Burge, H. A. (2002) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2002.128674 · Cited by 180
Effect of relative humidity on the aerodynamic diameter and respiratory deposition of fungal spores
Reponen, T., Willeke, K., Ulevicius, V., Reponen, A., & Grinshpun, S. A. (1996) · Atmospheric Environment · doi:10.1016/1352-2310(96)00128-8 · Cited by 170
Bioaerosols from composting facilities—a review
Wéry, N. (2014) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2014.00042 · Cited by 129
Aerodynamic versus physical size of spores: Measurement and implication for respiratory deposition
Reponen, T., Grinshpun, S. A., Conwell, K. L., Wiest, J., & Anderson, M. (2001) · Grana · doi:10.1080/00173130152625851 · Cited by 123
“…under a microto absorb water from the air and grow in their size (Pasanen scope (see Tables III and IV) shows that even the smallest et al. 1991, Madelin & Johnson 1992, Reponen et al. 1996). physical diameter (3.6 mm) is still 1.5 times larger than the Previous studies on the hygroscopic…”
ResultInfluential
Metadata
- Authors
- Madelin, T. M., & Johnson, H. E.
- Venue
- Journal of Applied Bacteriology
- Publisher
- Wiley
- Published
- 1992-05
- Volume
- 72
- Issue
- 5
- Pages
- 400-409
- ISSN
- 0021-8847 (ISSN-L)
- OpenAlex
- W2079833984
- Cited by
- 68
- References
- 0
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.