CoChat

Legionella waterline colonization: detection of Legionella species in domestic, hotel and hospital hot water systems

Leoni, E., De Luca, G., Legnani, P.P., Sacchetti, R., Stampi, S., Zanetti, F. · 2005 · Journal of Applied Microbiology
Cited by 192

The DOI matches its Crossref record.

Abstract

AIMS: An evaluation was made of the prevalence of Legionella species in hot water distribution systems in the city of Bologna (Italy) and their possible association with bacterial contamination (total counts and Pseudomonadaceae) and the chemical characteristics of the water (pH, Ca, Mg, Fe, Mn, Cu, Zn and Total Organic Carbon, TOC). METHODS AND RESULTS: A total of 137 hot water samples were analysed: 59 from the same number of private apartments, 46 from 11 hotels and 32 from five hospitals, all using the same water supply. Legionella species were detected in 40.0% of the distribution systems, L. pneumophila in 33.3%. The highest colonization was found in the hot water systems of hospitals (93.7% of samples positive for L. pneumophila, geometric mean: 2.4 x 10(3) CFU l(-1)), followed by the hotels (60.9%, geometric mean: 127.3 CFU l(-1)) and the apartments with centralized heating (41.9%, geometric mean: 30.5 CFU l(-1)). The apartments with independent heating systems showed a lower level of colonization (3.6% for Legionella species), with no evidence of L. pneumophila. Correlation analysis suggests that copper exerts an inhibiting action, while the TOC tends to favour the development of L. pneumophila. No statistically significant association was seen with Pseudomonadaceae, which were found at lower water temperatures than legionellae and in individual distribution points rather than in the whole network. CONCLUSIONS: The water recirculation system used by centralized boilers enhances the spreading of legionellae throughout the whole network, both in terms of the number of colonized sites and in terms of CFU count. SIGNIFICANCE AND IMPACT OF THE STUDY: Differences in Legionella colonization between types of buildings are not due to a variation in water supply but to other factors. Besides the importance of water recirculation, the study demonstrates the inhibiting action of copper and the favourable action of TOC on the development of L. pneumophila.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2672.2004.02458.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 192

Metadata

Authors
Leoni, E., De Luca, G., Legnani, P. P., Sacchetti, R., Stampi, S., & Zanetti, F.
Venue
Journal of Applied Microbiology
Published
2005-02
Volume
98
Issue
2
Pages
373-379
ISSN
  • 1364-5072 (ISSN-L)
  • 1365-2672
OpenAlex
W2104044285
Cited by
192
References
0
FWCI
4.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Legionella waterline colonization: detection of Legionella species in domestic, hotel and hospital hot water systems. https://app.cochat.ai/papers/10.1111/j.1365-2672.2004.02458.x
The paper
Leoni, E., De Luca, G., Legnani, P. P., Sacchetti, R., Stampi, S., & Zanetti, F. (2005). Legionella waterline colonization: detection of Legionella species in domestic, hotel and hospital hot water systems. Journal of Applied Microbiology. https://doi.org/10.1111/j.1365-2672.2004.02458.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.