The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
New water disinfection system using UVA light-emitting diodes: New disinfection system
Abstract
AIM: To evaluate the ability of high-energy ultraviolet A (UVA) light-emitting diode (LED) to inactivate bacteria in water and investigate the inactivating mechanism of UVA irradiation. METHODS AND RESULTS: We developed a new disinfection device equipped with high-energy UVA-LED. Inactivation of bacteria was determined by colony-forming assay. Vibrio parahaemolyticus, enteropathogenic Escherichia coli, Staphylococcus aureus and Escherichia coli DH5alpha were reduced by greater than 5-log(10) stages within 75 min at 315 J cm(-2) of UVA. Salmonella enteritidis was reduced greater than 4-log(10) stages within 160 min at 672 J cm(-2) of UVA. The formation of 8-hydroxy-2'-deoxyguanosine in UVA-LED irradiated bacteria was 2.6-fold higher than that of UVC-irradiated bacteria at the same inactivation level. Addition of mannitol, a scavenger of hydroxyl radicals (OH(*)), or catalase, an enzyme scavenging hydrogen peroxide (H(2)O(2)) to bacterial suspensions significantly suppressed disinfection effect of UVA-LED. CONCLUSION: This disinfection system has enough ability to inactivate bacteria and OH(*) and H(2)O(2) participates in the disinfection mechanism of UVA irradiation. SIGNIFICANCE AND IMPACT OF THE STUDY: We newly developed UVA irradiation system and found that UVA alone was able to disinfect the water efficiently. This will become a useful disinfection system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Douki, T., Reynaud-Angelin, A., Cadet, J., & Sage, E. (2003) · Biochemistry · doi:10.1021/bi034593c · Cited by 452
Brash, D. E., Seetharam, S., Kraemer, K. H., Seidman, M. M., & Bredberg, A. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.11.3782 · Cited by 237
Kozmin, S., Slezak, G., Reynaud-Angelin, A., Elie, C., de Rycke, Y., Boiteux, S., & Sage, E. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504497102 · Cited by 148
Cited by
Application of ultraviolet light-emitting diodes (UV-LEDs) for water disinfection: A review
Song, K., Mohseni, M., & Taghipour, F. (2016) · Water Research · doi:10.1016/j.watres.2016.03.003 · Cited by 858
LED revolution: fundamentals and prospects for UV disinfection applications
Chen, J., Loeb, S., & Kim, J.-H. (2017) · Environmental Science: Water Research & Technology · doi:10.1039/c6ew00241b · Cited by 331
Metadata
- Authors
- Hamamoto, A., Mori, M., Takahashi, A., Nakano, M., Wakikawa, N., Akutagawa, M., Ikehara, T., Nakaya, Y., & Kinouchi, Y.
- Venue
- Journal of Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-08-30
- Volume
- 103
- Issue
- 6
- Pages
- 2291-2298
- ISSN
- 1364-5072 (ISSN-L)
- OpenAlex
- W1541385703
- Cited by
- 178
- References
- 3
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New water disinfection system using UVA light-emitting diodes: New disinfection system. https://app.cochat.ai/papers/10.1111/j.1365-2672.2007.03464.x
- The paper
- Hamamoto, A., Mori, M., Takahashi, A., Nakano, M., Wakikawa, N., Akutagawa, M., Ikehara, T., Nakaya, Y., & Kinouchi, Y. (2007). New water disinfection system using UVA light-emitting diodes: New disinfection system. Journal of Applied Microbiology. https://doi.org/10.1111/j.1365-2672.2007.03464.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.