Abstract
AIMS: Studies to date have shown rapid killing of bacterial cells when exposed to copper surfaces. The mechanistic action of copper on bacterial cells is so far unknown. METHODS AND RESULTS: To investigate potential mechanisms involved, meticillin-resistant Staphylococcus aureus (MRSA) cells (10(7) CFU) were inoculated onto coupons of copper or stainless steel and stained with either the viability fluorophore 5-cyano-2,3-ditolyl tetrazolium (CTC), to detect respiration, or BacLight™ (SYTO9/propidium iodide), to determine cell wall integrity. Coupons were then observed in-situ using epifluorescence microscopy. In addition, DNA from cells inoculated onto either copper or stainless steel surfaces was isolated and analysed by agarose gel electrophoresis. An effect on cellular respiration with CTC reduction was evident but no effect on cell membrane integrity (BacLight™) was observed. Results from the DNA isolation indicated a copper-induced detrimental effect on MRSA genomic material as no bands were observed after exposure to copper surface. CONCLUSIONS: The results indicate that exposure to copper surfaces rapidly kills MRSA by compromising cellular respiration and damaging DNA, with little effect on cell membrane integrity. SIGNIFICANCE AND IMPACT OF THE STUDY: This research provides a mechanistic explanation in support of previous suggestions that although copper surfaces do not affect membrane integrity of cells, there is still a rapid antimicrobial effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxidative mechanisms in the toxicity of metal ions
Stohs, S. J., & Bagchi, D. (1995) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(94)00159-h · Cited by 4,219 · cited 2×
“The rapid inactivation of microorganisms exposed to copper has to date been attributed to either one or a combination of the following mechanisms; loss of structural integrity of the cell membrane, alteration to the conformational structure of proteins or degradation of the cellular DNA and or RNA (Stohs and Bagchi 19…”
BackgroundBoulos, L., Prévost, M., Barbeau, B., Coallier, J., & Desjardins, R. (1999) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(99)00048-2 · Cited by 1,125 · cited 11×
“To elucidate a potential method of the action of copper ions on or in cell’s survival of MRSA on copper alloys and stainless steel using viability fluorophores designed to detect cellular respiration, 5-cyano-2,3-ditolyl tetrazolium (CTC) (Boulos et al. 1999), cell wall integrity BacLightTM (Noyce et al. 2006), cultur…”
MethodInfluentialNoyce, J. O., Michels, H., & Keevil, C. W. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2005.12.008 · Cited by 403 · cited 9×
“Coupons of stainless steel and copper were inoculated with 20 ll of the 16-h culture and air-dried rapidly, in a flow of air (Class II cabinet), as described previously (Noyce et al. 2006).”
BackgroundMethodSelf-citationHandwashing—the Semmelweis lesson forgotten?
Jarvis, W. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90687-4 · Cited by 233
Cited by
Contact killing and antimicrobial properties of copper
Vincent, M., Duval, R. E., Hartemann, P., & Engels‐Deutsch, M. (2018) · Journal of Applied Microbiology · doi:10.1111/jam.13681 · Cited by 694
Copper Surfaces Reduce the Rate of Healthcare-Acquired Infections in the Intensive Care Unit
Salgado, C. D., Sepkowitz, K. A., John, J. F., Cantey, J. R., Attaway, H. H., Freeman, K. D., Sharpe, P. A., Michels, H. T., & Schmidt, M. G. (2013) · Infection Control & Hospital Epidemiology · doi:10.1086/670207 · Cited by 366
Self-citationRole of Copper Oxides in Contact Killing of Bacteria
Hans, M., Erbe, A., Mathews, S., Chen, Y., Solioz, M., & Mücklich, F. (2013) · Langmuir · doi:10.1021/la404091z · Cited by 360
Membrane Lipid Peroxidation in Copper Alloy-Mediated Contact Killing of Escherichia coli
Hong, R., Kang, T. Y., Michels, C. A., & Gadura, N. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.07068-11 · Cited by 278
Mathews, S., Hans, M., Mücklich, F., & Solioz, M. (2013) · Applied and Environmental Microbiology · doi:10.1128/aem.03608-12 · Cited by 214
“This was shown for several organisms and by a variety of techniques, including direct microscopic examination of cells (16, 30) using redox dyes like 5-cyano-2,3-ditolyl tetrazolium chloride or rhodamine 123 staining of respiring cells (4, 19, 20), or by the Live/Dead staining technique, which combines the green fluor…”
BackgroundMethod
Metadata
- Authors
- Weaver, L., Noyce, J. O., Michels, H. T., & Keevil, C. W.
- Venue
- Journal of Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-10-11
- Volume
- 109
- Issue
- 6
- Pages
- 2200-2205
- ISSN
- 1364-5072 (ISSN-L)
- OpenAlex
- W1709170383
- Cited by
- 135
- References
- 4
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.