Prevalence and type of pre‐analytical problems for inpatients samples in coagulation laboratory
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Rationale, aims and objectives Total quality in coagulation testing is a necessary requisite to achieve clinically reliable results. Evidence was provided that poor standardization in the extra‐analytical phases of the testing process has the greatest influence on test results, though little information is available so far on prevalence and type of pre‐analytical variability in coagulation testing. Methods The present study was designed to describe all pre‐analytical problems on inpatients routine and stat samples recorded in our coagulation laboratory over a 2‐year period and clustered according to their source (hospital departments). Results Overall, pre‐analytic problems were identified in 5.5% of the specimens. Although the highest frequency was observed for paediatric departments, in no case was the comparison of the prevalence among the different hospital departments statistically significant. The more frequent problems could be referred to samples not received in the laboratory following a doctor’s order (49.3%), haemolysis (19.5%), clotting (14.2%) and inappropriate volume (13.7%). Specimens not received prevailed in the intensive care unit, surgical and clinical departments, whereas clotted and haemolysed specimens were those most frequently recorded from paediatric and emergency departments, respectively. The present investigation demonstrates a high prevalence of pre‐analytical problems affecting samples for coagulation testing. Conclusions Full implementation of a total quality system, encompassing a systematic error tracking system, is a valuable tool to achieve meaningful information on the local pre‐analytic processes most susceptible to errors, enabling considerations on specific responsibilities and providing the ideal basis for an efficient feedback within the hospital departments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Cited by
Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories
Lippi, G., Plebani, M., Di Somma, S., & Cervellin, G. (2011) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2011.600228 · Cited by 226
Self-citationThe cost of poor blood specimen quality and errors in preanalytical processes
Green, S. F. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2013.06.001 · Cited by 206
“The most frequently encountered causes of preanalytical errors are hemolysis, incorrect patient identification, insufficient sample volume, and clotted specimens [13].”
BackgroundLima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2012) · Biochemia Medica · doi:10.11613/bm.2012.036 · Cited by 66
Self-citationWoolley, A., Golmard, J. ‐., & Kitchen, S. (2016) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12498 · Cited by 47
“respectively, of samples referred to coagulation laboratories [11].”
BackgroundElimination of the venous stasis error for routine coagulation testing by transillumination
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Montagnana, M., Scartezini, M., Picheth, G., & Guidi, G. C. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.04.008 · Cited by 38
Self-citation
Metadata
- Authors
- Salvagno, G. L., Lippi, G., Bassi, A., Poli, G., & Guidi, G. C.
- Venue
- Journal of Evaluation in Clinical Practice
- Publisher
- Wiley
- Published
- 2008-03-06
- Volume
- 14
- Issue
- 2
- Pages
- 351-353
- ISSN
- 1356-1294 (ISSN-L)
- 1365-2753
- OpenAlex
- W2076034098
- Cited by
- 79
- References
- 1
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prevalence and type of pre‐analytical problems for inpatients samples in coagulation laboratory. https://app.cochat.ai/papers/10.1111/j.1365-2753.2007.00875.x
- The paper
- Salvagno, G. L., Lippi, G., Bassi, A., Poli, G., & Guidi, G. C. (2008). Prevalence and type of pre‐analytical problems for inpatients samples in coagulation laboratory. Journal of Evaluation in Clinical Practice. https://doi.org/10.1111/j.1365-2753.2007.00875.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.