The DOI matches its Crossref record.
Video‐enhanced microscopy with a computer frame memory
Abstract
SUMMARY: Video‐enhanced microscopy combined with the use of a computer frame memory extends considerably the useful range of our video enhanced contrast (AVEC) methods for polarizing, double‐beam interference and differential interference contrast microscopy. Increased visual contrast is achieved by two stages of amplifications: the first optical, by using high bias retardation settings, and the second electronic. These steps are followed by a reduction of background brightness by means of a clamp voltage applied to a DC restoration circuit of the video camera. One of the limitations of the AVEC method alone is the inevitable appearance under high gain conditions of a pattern of mottle due to inaccessible dirt and defects in the lenses even of high quality. This limitation has been circumvented by storing the mottle pattern in the frame memory (frame store) and continuously subtracting it from each succeeding frame to clear the image. A major gain in image quality has resulted. In polarizing microscopy, the frame memory can be used also to subtract the image at one compensator setting from that at the equivalent setting of opposite sign, thus removing from the final image not only most of the mottle pattern but also the contrast due to the bright‐field contrast. In the polarizing microscope, these manipulations of the raw video image make it possible to observe and measure the birefringence of various organelles and elements such as microtubules, intermediate filaments and bundles of as few as a half dozen actin filaments. Since scattered light is also removed from the image, features hidden from view in the unprocessed image become visible. In differential interference microscopy, the AVEC method makes visible (i.e. detectable) many linear elements and particles that are an order of magnitude smaller than the resolution limit and not visible in the optical image. Such features are inflated by diffraction, however, to Airy disk size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Allen, R. D., Weiss, D. G., Hayden, J. H., Brown, D. T., Fujiwake, H., & Simpson, M. (1985) · The Journal of cell biology · doi:10.1083/jcb.100.5.1736 · Cited by 441
Self-citationBovine brain kinesin is a microtubule-activated ATPase
Kuznetsov, S. A., & Gelfand, V. I. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.22.8530 · Cited by 217
Metadata
- Authors
- Allen, R. D., & Allen, N. S.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1983-01
- Volume
- 129
- Issue
- 1
- Pages
- 3-17
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2034992618
- Cited by
- 187
- References
- 0
- FWCI
- 16.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Video‐enhanced microscopy with a computer frame memory. https://app.cochat.ai/papers/10.1111/j.1365-2818.1983.tb04157.x
- The paper
- Allen, R. D., & Allen, N. S. (1983). Video‐enhanced microscopy with a computer frame memory. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1983.tb04157.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.