Sampling problems in an heterogeneous organ: Quantitation of relative and total volume of pancreatic islets by light microscopy
The DOI matches its Crossref record.
Abstract
SUMMARY: In stereological studies analysis of sampling variances is used for optimizing the sampling design. In organs with a heterogeneous distribution of the phase of interest the analysis of sampling variances can be undertaken only if the observed variance between sections is distributed into the fraction which is due to random variation and the fraction which is due to the heterogeneity. In the present example (pancreatic islet volume estimated by light microscopic point‐counting) the density of islets showed a linear increase along the axis of the organ. By analysis of sampling variances it was calculated that the most efficient number of sections (cut perpendicular to the organ) was considerably lower when the isolated contribution from the random variation was considered. The total islet volume was obtained by the product of the fractional islet volume and the pancreatic weight. Analysis of sampling variances of the total islet volume was performed by including the variance contribution from the individual pancreatic weights to the variance of the group mean total islet volume. Due to a negative correlation between the fractional volume and organ weight the total islet volume in the group of animals was more precisely estimated than the fractional islet volume. The methods used for dealing with the heterogeneity of the organ and for estimating sampling variances of total structural quantities generalize to a large number of stereological studies in biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The efficiency of systematic sampling in stereology and its prediction*
Gundersen, H. J. G., & Jensen, E. B. (1987) · Journal of Microscopy · doi:10.1111/j.1365-2818.1987.tb02837.x · Cited by 3,520
Self-citationGundersen, H. J. G. (1986) · Journal of Microscopy · doi:10.1111/j.1365-2818.1986.tb02764.x · Cited by 1,429
Self-citationUnbiased stereological estimation of the number of neurons in the human hippocampus
West, M. J., & Gundersen, H. J. G. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902960102 · Cited by 1,153
Self-citationEstimation of surface area from vertical sections
Baddeley, A. J., Gundersen, H. J. G., & Cruz‐Orive, L. M. (1986) · Journal of Microscopy · doi:10.1111/j.1365-2818.1986.tb04282.x · Cited by 1,058
Self-citationThe impact of recent stereological advances on quantitative studies of the nervous system
Brændgaard, H., & Gundersen, H. J. G. (1986) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(86)90112-3 · Cited by 503
Self-citation
Metadata
- Authors
- Kroustrup, J. P., & Gundersen, H. J. G.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1983-10
- Volume
- 132
- Issue
- 1
- Pages
- 43-55
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2005182406
- Cited by
- 77
- References
- 0
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sampling problems in an heterogeneous organ: Quantitation of relative and total volume of pancreatic islets by light microscopy. https://app.cochat.ai/papers/10.1111/j.1365-2818.1983.tb04707.x
- The paper
- Kroustrup, J. P., & Gundersen, H. J. G. (1983). Sampling problems in an heterogeneous organ: Quantitation of relative and total volume of pancreatic islets by light microscopy. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1983.tb04707.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.