CoChat

A synchrotron X‐ray study of the changes occurring in the corneal stroma during processing for electron microscopy

FULLWOOD, N. J., MEEK, K. M. · 1993 · Journal of Microscopy
Cited by 48

The DOI matches its Crossref record.

Abstract

SUMMARY: Using a high‐intensity synchrotron X‐ray source, the structural changes occurring in the corneal stroma were monitored during each stage of several different processing runs for the transmission electron microscope (TEM) and scanning electron microscope (SEM). The parameters studied were interfibrillar spacing, intermolecular spacing, D‐periodicity and fibril diameter. The processing schedule that produced the least changes in spacings for TEM specimens involved extended fixation in glutaraldehyde followed by low‐temperature embedding in Lowicryl K4M resin. However, interfibrillar material was better preserved after embedding in LR White resin or Nanoplast. Almost every processing stage for electron microscopy produced significant changes in one or more structural parameters in the cornea. Glutaraldehyde fixation significantly increased the intermolecular spacings, while resin infiltration and resin polymerization each resulted in shrinkage of all the spacings monitored. Critical‐point drying for SEM specimens resulted in considerable shrinkage in all three spacings, but was still preferable to air drying, which caused reduction in the order of the fibril packing, resulting in loss of the interfibrillar X‐ray pattern. Perhaps the most drastic effect was caused by post‐fixation in osmium tetroxide, which resulted in loss of the intermolecular pattern, and also increased the amount of shrinkage in the interfibrillar spacings and the D‐periodicity which occurred during later stages of processing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2818.1993.tb03277.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 48

Metadata

Authors
FULLWOOD, N. J., & MEEK, K. M.
Venue
Journal of Microscopy
Publisher
Wiley
Published
1993-01
Volume
169
Issue
1
Pages
53-60
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W2017136381
Cited by
48
References
0
FWCI
1.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A synchrotron X‐ray study of the changes occurring in the corneal stroma during processing for electron microscopy. https://app.cochat.ai/papers/10.1111/j.1365-2818.1993.tb03277.x
The paper
FULLWOOD, N. J., & MEEK, K. M. (1993). A synchrotron X‐ray study of the changes occurring in the corneal stroma during processing for electron microscopy. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1993.tb03277.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.