Orthogonal‐plane fluorescence optical sectioning: Three‐dimensional imaging of macroscopic biological specimens
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Summary: An imaging technique called orthogonal‐plane fluorescence optical sectioning (OPFOS) was developed to image the internal architecture of the cochlea. Expressions for the three‐dimensional point spread function and the axial and lateral resolution are derived. Methodologies for tissue preparation and for construction, alignment, calibration and characterization of an OPFOS apparatus are presented. The instrument described produced focused, high‐resolution images of optical sections of an intact, excised guineapig cochlea. The lateral and axial resolutions of the images were 10 and 26 μm, respectively, within a 1·5‐mm field of view.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marlow, B. K. (1979) · Optica Acta: International Journal of Optics · doi:10.1080/716099475 · Cited by 1,004
Chapter 13 Fluorescence Microscopy in Three Dimensions
Agard, D. A., Hiraoka, Y., Shaw, P., & Sedat, J. W. (1989) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)60986-3 · Cited by 649
Optical Sectioning Microscopy: Cellular Architecture in Three Dimensions
Agard, D. A. (1984) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.13.060184.001203 · Cited by 475
Inoué, S. (1986) · Springer eBooks · doi:10.1007/978-1-4757-6925-8 · Cited by 342
Hiraoka, Y., Sedat, J. W., & Agard, D. A. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82534-0 · Cited by 261
Three-dimensional imaging in fluorescence by confocal scanning microscopy
Brakenhoff, G. J., van der Voort, H. T. M., van Spronsen, E. A., & Nanninga, N. (1989) · Journal of Microscopy · doi:10.1111/j.1365-2818.1989.tb00555.x · Cited by 90
Cited by
Nanometer resolution imaging and tracking of fluorescent molecules with minimal photon fluxes
Balzarotti, F., Eilers, Y., Gwosch, K. C., Gynnå, A. H., Westphal, V., Stefani, F. D., Elf, J., & Hell, S. W. (2017) · Science · doi:10.1126/science.aak9913 · Cited by 1,225
Scale: a chemical approach for fluorescence imaging and reconstruction of transparent mouse brain
Hama, H., Kurokawa, H., Kawano, H., Ando, R., Shimogori, T., Noda, H., Fukami, K., Sakaue-Sawano, A., & Miyawaki, A. (2011) · Nature Neuroscience · doi:10.1038/nn.2928 · Cited by 1,142
Microscopy with self-reconstructing beams
Fahrbach, F. O., Simon, P., & Rohrbach, A. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.204 · Cited by 697
Tissue clearing and its applications in neuroscience
Ueda, H. R., Ertürk, A., Chung, K., Gradinaru, V., Chédotal, A., Tomancak, P., & Keller, P. J. (2020) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0250-1 · Cited by 609
Selective plane illumination microscopy techniques in developmental biology
Huisken, J., & Stainier, D. Y. R. (2009) · Development · doi:10.1242/dev.022426 · Cited by 608
Metadata
- Authors
- VOIE, A. H., BURNS, D. H., & SPELMAN, F. A.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1993-06
- Volume
- 170
- Issue
- 3
- Pages
- 229-236
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2040870938
- Cited by
- 477
- References
- 6
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.