Unbiased estimation of human body composition by the Cavalieri method using magnetic resonance imaging
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Summary: The classical methods for estimating the volume of human body compartments in vivo (e.g. skin‐fold thickness for fat, radioisotope counting for different compartments, etc.) are generally indirect and rely on essentially empirical relationships — hence they are biased to unknown degrees. The advent of modern non‐invasive scanning techniques, such as X‐ray computed tomography (CT) and magnetic resonance imaging (MRI) is now widening the scope of volume quantification, especially in combination with stereological methods. Apart from its superior soft tissue contrast, MRI enjoys the distinct advantage of not using ionizing radiations. By a proper landmarking and control of the scanner couch, an adult male volunteer was scanned exhaustively into parallel systematic MR ‘sections’. Four compartments were defined, namely bone, muscle, organs and fat (which included the skin), and their corresponding volumes were easily and efficiently estimated by the Cavalieri method: the total section area of a compartment times the section interval estimates the volume of the compartment without bias. Formulae and nomograms are given to predict the errors and to optimize the design. To estimate an individual's muscle volume with a 5% coefficient of error, 10 sections and less than 10min point counting (to estimate the relevant section areas) are required. Bone and fat require about twice as much work. To estimate the mean muscle volume of a population with the same error contribution, from a random sample of six subjects, the workload per subject can be divided by √6, namely 4 min per subject. For a given number of sections planimetry would be as accurate but far more time consuming than point counting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The efficiency of systematic sampling in stereology and its prediction*
Gundersen, H. J. G., & Jensen, E. B. (1987) · Journal of Microscopy · doi:10.1111/j.1365-2818.1987.tb02837.x · Cited by 3,520
A simple method for volumetry of organs in quantitative stereology.
Scherle, W. F. (1970) · PubMed · Cited by 1,047
Stereological methods. Vol. 1: Practical methods for biological morphometry
Hung, G. W. C. (1984) · Microchemical Journal · doi:10.1016/0026-265x(84)90124-3 · Cited by 627
Optimizing sampling efficiency of stereological studies in biology: or ‘Do more less well!‘
Gundersen, H. J. G., & ØSterby, R. (1981) · Journal of Microscopy · doi:10.1111/j.1365-2818.1981.tb01199.x · Cited by 534
Michel, R. P., & Cruz‐Orive, L. M. (1988) · Journal of Microscopy · doi:10.1111/j.1365-2818.1988.tb04603.x · Cited by 431
Self-citationMathieu, O., Cruz‐Orive, L. M., Hoppeler, H., & Weibel, E. R. (1981) · Journal of Microscopy · doi:10.1111/j.1365-2818.1981.tb01200.x · Cited by 218
Self-citationMayhew, T. M., & Olsen, D. R. (1991) · PubMed Central · Cited by 213
Estimation of body volume by underwater weighing: description of a simple method.
Katch, F., Michael, E. D., & Horvath, S. M. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.5.811 · Cited by 183
Comparison of semiautomatic digitizer-tablet and simple point counting performance in morphometry
Gundersen, H. J. G., Boysen, M., & Reith, A. (1981) · Virchows Archiv B Cell Pathology Including Molecular Pathology · doi:10.1007/bf02892580 · Cited by 145
Techniques of Measurement of Body Composition: Part I1
Brodie, D. A. (1988) · Sports Medicine · doi:10.2165/00007256-198805010-00003 · Cited by 125
Self-citationNew approaches to body composition
Garrow, J. S. (1982) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/35.5.1152 · Cited by 115
On the precision of systematic sampling: a review of Matheron's transitive methods
Cruz-Orive, L. M. (1989) · Journal of Microscopy · doi:10.1111/j.1365-2818.1989.tb01480.x · Cited by 95 · cited 4×
“Curves exhibiting a ‘dome shape’, vanishing at the end points, are ideal for systematic sampling and estimation (Gundersen & Jensen, 1987: Ogbuihi & Cruz-Orive, 1990, section 5). On the contrary, compartments exhibiting relatively large sections near the ends-as may be the case for a leg near the hip-may be inefficien…”
Self-citationVertical LM sectioning and parallel CT scanning designs for stereology: application to human lung
Pache, J., Roberts, N., Vock, P., Zimmermann, A., & Cruz-Orive, L. M. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03319.x · Cited by 79
Self-citationThe skinfold: Myth and reality∗
Clarys, J. P., Martin, A. D., Drinkwater, D. T., & Marfell-Jones, M. (1987) · Journal of Sports Sciences · doi:10.1080/02640418708729760 · Cited by 75
Maughan, R. J., Watson, J. S., & Weir, J. (1984) · Clinical Science · doi:10.1042/cs0660683 · Cited by 68
Pakkenberg, B., Boesen, J., Albeck, M., & Gjerris, F. (1989) · Neuroradiology · doi:10.1007/bf00343866 · Cited by 67
The Measurement of Body Composition
Malina, R. M. (1980) · Springer eBooks · doi:10.1007/978-1-4684-6994-3_4 · Cited by 54
Stereological estimation of volume ratios by systematic sections
Cruz-Orive, L. M., & Myking, A. O. (1981) · Journal of Microscopy · doi:10.1111/j.1365-2818.1981.tb01253.x · Cited by 42
Self-citationTechniques of Measurement of Body Composition
Brodie, D. A. (1988) · Sports Medicine · doi:10.2165/00007256-198805020-00002 · Cited by 39
Self-citationEstimating the total number of lymphatic valves in infant lungs with the fractionator
Ogbuihi, S., & Cruz-Orive, L. M. (1990) · Journal of Microscopy · doi:10.1111/j.1365-2818.1990.tb02973.x · Cited by 34
Self-citationThe accuracy of one‐dimensional systematic sampling
Mattfeldt, T. (1989) · Journal of Microscopy · doi:10.1111/j.1365-2818.1989.tb01479.x · Cited by 31
MORGAN, D. B., & Burkinshaw, L. (1983) · Clinical Science · doi:10.1042/cs0650407 · Cited by 31
Cited by
West, M. J. (1999) · Trends in Neurosciences · doi:10.1016/s0166-2236(98)01362-9 · Cited by 827
Design-based stereology in neuroscience
Schmitz, C., & Hof, P. R. (2005) · Neuroscience · doi:10.1016/j.neuroscience.2004.08.050 · Cited by 681
Boyd-Clark, L. C., Briggs, C. A., & Galea, M. P. (2002) · Spine · doi:10.1097/00007632-200204010-00005 · Cited by 357
An Image-Processing System for Qualitative and Quantitative Volumetric Analysis of Brain Images
Goldszal, A. F., Davatzikos, C., Pham, D. L., Yan, M. X. H., Bryan, R. N., & Resnick, S. M. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199809000-00030 · Cited by 295
Holdstock, J. S., Mayes, A. R., Cezayirli, E., Isaac, C. L., Aggleton, J. P., & Roberts, N. (2000) · Neuropsychologia · doi:10.1016/s0028-3932(99)00099-8 · Cited by 253
Self-citation
Metadata
- Authors
- ROBERTS, N., CRUZ‐ORIVE, L. M., REID, N. M. K., BRODIE, D. A., BOURNE, M., & EDWARDS, R. H. T.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1993-09
- Volume
- 171
- Issue
- 3
- Pages
- 239-253
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2062685926
- Cited by
- 165
- References
- 22
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.