Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 336

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Confocal imaging of glutathione redox potential in living plant cells

SCHWARZLÄNDER, M., FRICKER, M.D., MÜLLER, C., MARTY, L., BRACH, T., NOVAK, J., SWEETLOVE, L.J., HELL, R., MEYER, A.J.·2008·Journal of Microscopy

Abstract

Summary: Reduction–oxidation‐sensitive green fluorescent protein (roGFP1 and roGFP2) were expressed in different sub‐cellular compartments of Arabidopsis and tobacco leaves to empirically determine their performance as ratiometric redox sensors for confocal imaging in planta. A lower redox‐dependent change in fluorescence in combination with reduced excitation efficiency at 488 nm resulted in a significantly lower dynamic range of roGFP1 than for roGFP2. Nevertheless, when targeted to the cytosol and mitochondria of Arabidopsis leaves both roGFPs consistently indicated redox potentials of about –320 mV in the cytosol and –360 mV in the mitochondria after pH correction for the more alkaline matrix pH. Ratio measurements were consistent throughout the epidermal cell layer, but results might be attenuated deeper within the leaf tissue. Specific interaction of both roGFPs with glutaredoxin in vitro strongly suggests that in situ both variants preferentially act as sensors for the glutathione redox potential. roGFP2 targeted to plastids and peroxisomes in epidermal cells of tobacco leaves was slightly less reduced than in other plasmatic compartments, but still indicated a highly reduced glutathione pool. The only oxidizing compartment was the lumen of the endoplasmic reticulum, in which roGFP2 was almost completely oxidized. In all compartments tested, roGFP2 reversibly responded to perfusion with H 2 O 2 and DTT, further emphasizing that roGFP2 is a reliable probe for dynamic redox imaging in planta. Reliability of roGFP1 measurements might be obscured though in extended time courses as it was observed that intense irradiation of roGFP1 at 405 nm can lead to progressive photoisomerization and thus a redox‐independent change of fluorescence excitation ratios.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2818.2008.02030.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 336

Metadata

Authors
SCHWARZLÄNDER, M., FRICKER, M. D., MÜLLER, C., MARTY, L., BRACH, T., NOVAK, J., SWEETLOVE, L. J., HELL, R., & MEYER, A. J.
Venue
Journal of Microscopy
Publisher
Wiley
Published
2008-07-31
Volume
231
Issue
2
Pages
299-316
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W1993358648
Cited by
336
References
4
FWCI
5.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Confocal imaging of glutathione redox potential in living plant cells. https://app.cochat.ai/papers/10.1111/j.1365-2818.2008.02030.x
The paper
SCHWARZLÄNDER, M., FRICKER, M. D., MÜLLER, C., MARTY, L., BRACH, T., NOVAK, J., SWEETLOVE, L. J., HELL, R., & MEYER, A. J. (2008). Confocal imaging of glutathione redox potential in living plant cells. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.2008.02030.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.