Transmission EBSD from 10 nm domains in a scanning electron microscope
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Summary: The spatial resolution of electron diffraction within the scanning electron microscope (SEM) has progressed from channelling methods capable of measuring crystallographic characteristics from 10 μm regions to electron backscatter diffraction (EBSD) methods capable of measuring 120 nm particles. Here, we report a new form of low‐energy transmission Kikuchi diffraction, performed in the SEM. Transmission‐EBSD (t‐EBSD) makes use of an EBSD detector and software to capture and analyse the angular intensity variation in large‐angle forward scattering of electrons in transmission, without postspecimen coils. We collected t‐EBSD patterns from Fe–Co nanoparticles of diameter 10 nm and from 40 nm‐thick Ni films with in‐plane grain size 15 nm. The patterns exhibited contrast similar to that seen in EBSD, but are formed in transmission. Monte Carlo scattering simulations showed that in addition to the order of magnitude improvement in spatial resolution from isolated particles, the energy width of the scattered electrons in t‐EBSD is nearly two orders of magnitude narrower than that of conventional EBSD. This new low‐energy transmission diffraction approach builds upon recent progress in achieving unprecedented levels of imaging resolution for materials characterization in the SEM by adding high‐spatial‐resolution analytical capabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electron Backscatter Diffraction in Materials Science
(2009) · Springer eBooks · doi:10.1007/978-0-387-88136-2 · Cited by 1,753
Drouin, D., Couture, A. R., Joly, D., Tastet, X., Aimez, V., & Gauvin, R. (2007) · Scanning · doi:10.1002/sca.20000 · Cited by 1,552
Review Grain and subgrain characterisation by electron backscatter diffraction
Humphreys, F. J. (2001) · Journal of Materials Science · doi:10.1023/a:1017973432592 · Cited by 1,054
Scanning Electron Microscopy: Physics of Image Formation and Microanalysis
Reimer, L. (1998) · Springer Series in Optical Sciences · doi:10.1007/978-3-540-38967-5 · Cited by 798
Microtexture determination by electron back-scatter diffraction
Dingley, D. J., & Randle, V. (1992) · Journal of Materials Science · doi:10.1007/bf01165988 · Cited by 400
Cited by
Huang, K., Marthinsen, K., Zhao, Q., & Logé, R. E. (2018) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.10.004 · Cited by 788
Trimby, P. W. (2012) · Ultramicroscopy · doi:10.1016/j.ultramic.2012.06.004 · Cited by 403
Influence of Ti and Cr Adhesion Layers on Ultrathin Au Films
Todeschini, M., Bastos da Silva Fanta, A., Jensen, F., Wagner, J. B., & Han, A. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b10136 · Cited by 289
Atom Probe Tomography: Development and Application to the Geosciences
Reddy, S. M., Saxey, D. W., Rickard, W. D. A., Fougerouse, D., Montalvo, S. D., Verberne, R., & van Riessen, A. (2020) · Geostandards and Geoanalytical Research · doi:10.1111/ggr.12313 · Cited by 161
Peuble, S., Andreani, M., Godard, M., Gouze, P., Barou, F., Van de Moortele, B., Mainprice, D., & Reynard, B. (2015) · American Mineralogist · doi:10.2138/am-2015-4913 · Cited by 44
Metadata
- Authors
- KELLER, R. R., & GEISS, R. H.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2011-11-17
- Volume
- 245
- Issue
- 3
- Pages
- 245-251
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W1576261241
- Cited by
- 396
- References
- 5
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.