CoChat

Wrist actigraphic scoring for sleep laboratory patients: algorithm development: Wrist actigraphic algorithm development

KRIPKE, DANIEL F., HAHN, ELIZABETH K., GRIZAS, ALEXANDRA P., WADIAK, KEP H., LOVING, RICHARD T., POCETA, J. STEVEN, SHADAN, FARHAD F., CRONIN, JOHN W., KLINE, LAWRENCE E. · 2010 · Journal of Sleep Research
Cited by 103

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Wrist actigraphy is employed increasingly in sleep research and clinical sleep medicine. Critical evaluation of the performance of new actigraphs and software is needed. Actigraphic sleep-wake estimation was compared with polysomnographic (PSG) scoring as the standard in a clinical sleep laboratory. A convenience sample of 116 patients undergoing clinical sleep recordings volunteered to participate. Actiwatch-L recordings were obtained from 98 participants, along with 18 recordings using the newer Spectrum model (Philips Electronics), but some of the actigraphic recordings could not be adequately aligned with the simultaneous PSGs. Of satisfactory alignments, 40 Actiwatch recordings were used as a training set to empirically develop a new Scripps Clinic algorithm for sleep-wake scoring. The Scripps Clinic algorithm was then prospectively evaluated in 39 Actiwatch recordings and 16 Spectrum recordings, producing epoch-by-epoch sleep-wake agreements of 85-87% and kappa statistics averaging 0.52 (indicating moderate agreement). Wake was underestimated by the scoring algorithm. The correlations of PSG versus actigraphic wake percentage estimates were r = 0.6690 for the Actiwatch and r = 0.2197 for the Spectrum. In general, using a different weighting of activity counts from previous and subsequent epochs, the Scripps Clinic algorithm discriminated sleep-wake more successfully than the manufacturer's Actiware algorithms. Neither algorithm had fully satisfactory agreement with PSG. Further evaluations of algorithms for these actigraphs are needed, along with controlled comparisons of different actigraphic designs and software.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2869.2010.00835.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 103

Metadata

Authors
KRIPKE, D. F., HAHN, E. K., GRIZAS, A. P., WADIAK, K. H., LOVING, R. T., POCETA, J. S., SHADAN, F. F., CRONIN, J. W., & KLINE, L. E.
Venue
Journal of Sleep Research
Publisher
Wiley
Published
2010-04-07
Volume
19
Issue
4
Pages
612-619
ISSN
0962-1105 (ISSN-L)
OpenAlex
W1600151260
Cited by
103
References
2
FWCI
4.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wrist actigraphic scoring for sleep laboratory patients: algorithm development: Wrist actigraphic algorithm development. https://app.cochat.ai/papers/10.1111/j.1365-2869.2010.00835.x
The paper
KRIPKE, D. F., HAHN, E. K., GRIZAS, A. P., WADIAK, K. H., LOVING, R. T., POCETA, J. S., SHADAN, F. F., CRONIN, J. W., & KLINE, L. E. (2010). Wrist actigraphic scoring for sleep laboratory patients: algorithm development: Wrist actigraphic algorithm development. Journal of Sleep Research. https://doi.org/10.1111/j.1365-2869.2010.00835.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.