CoChat

Actigraphic assessment of a polysomnographic-recorded nap: a validation study: Actigraphic assessment of a nap

Open access
KANADY, JENNIFER C., DRUMMOND, SEAN P. A., MEDNICK, SARA C. · 2011 · Journal of Sleep Research
Cited by 101

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

This study aimed to determine if actigraphy could differentiate sleep and wake during a daytime nap and no-nap rest period. Fifty-seven subjects participated in the study; 30 subjects were in the nap group and the remaining 27 in the no-nap comparison group. All subjects wore actigraphs while simultaneously undergoing polysomnography (PSG). Three actigraphic sensitivity levels (high, medium, low) and two interval duration minimums (15 and 40 min) were used to score the nap and no-nap data. The variables examined included total sleep time (TST), sleep latency (SL), wake after sleep onset (WASO) and sleep efficiency (SE). The Bland-Altman technique was used to determine concordance. Epoch-by-epoch analysis examined actigraphic accuracy, sensitivity and specificity. For the naps, all actigraph settings except low-40 showed significant correlations with TST. The high and medium settings predicted SE significantly and the high settings predicted SL significantly. Bland-Altman analyses demonstrated high settings overestimated TST while high and medium settings overestimated SE. Overall, for the nap condition accuracy for the actigraph was 82-86%, sensitivity was 92-96% and specificity was 40-67%. In the no-nap condition, accuracy for the actigraph was 60-84%, sensitivity was 47-78% and specificity was 60-86%. Medium-40 and low-40 were the only settings that did not misidentify sleep in the no-nap condition. These results suggest that actigraphy can predict TST, SE and SL reliably, depending upon parameter settings, and actigraphy is a highly sensitive but not specific measure for daytime naps. Different actigraphy settings may be optimal depending upon the variables of interest. Discrimination of sleep and wake during periods of waking quiescence is not as robust as during periods of mainly daytime sleep.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2869.2010.00858.x

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 101

Metadata

Authors
KANADY, J. C., DRUMMOND, S. P. A., & MEDNICK, S. C.
Venue
Journal of Sleep Research
Publisher
Wiley
Published
2011-02-15
Volume
20
Issue
1pt2
Pages
214-222
ISSN
0962-1105 (ISSN-L)
OpenAlex
W1544688265
Cited by
101
References
6
FWCI
5.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Actigraphic assessment of a polysomnographic-recorded nap: a validation study: Actigraphic assessment of a nap. https://app.cochat.ai/papers/10.1111/j.1365-2869.2010.00858.x
The paper
KANADY, J. C., DRUMMOND, S. P. A., & MEDNICK, S. C. (2011). Actigraphic assessment of a polysomnographic-recorded nap: a validation study: Actigraphic assessment of a nap. Journal of Sleep Research. https://doi.org/10.1111/j.1365-2869.2010.00858.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.