CoChat

Cryo‐electron microscopy of cell division in Staphylococcus aureus reveals a mid‐zone between nascent cross walls

Matias, Valério R. F., Beveridge, Terry J. · 2007 · Molecular Microbiology
Cited by 92

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Summary: Cryo‐electron microscopy of frozen‐hydrated thin sections permits the observation of the real distribution of mass in biological specimens allowing the native structure of bacteria to be seen, including the natural orientation of their surface layers. Here, we use this approach to study the fine ultrastructure of the division site, or septum, of Staphylococcus aureus D 2 C. Frozen‐hydrated sections revealed a differentiated cell wall at the septum, showing two high‐density regions sandwiched between three low‐density zones. The two zones adjacent to the membrane appeared as an extension of the periplasmic space seen in this organism's cell envelope and showed no distinguishing structures within them. Immediately next to these were higher‐density zones that corresponded to nascent cross walls of the septum. Unexpectedly, a rather broad low‐density zone was seen separating cross walls in the septum. This mid‐zone of low density appeared inflated and without visible structures in isolated cell walls, which showed only the high‐density zones of the septum. Here, we suggest that frozen‐hydrated thin sections have captured a highly fragile septal region, the mid‐zone, which results from the dynamic action of autolysis and actively separates daughter cells during division. The two zones next to the membranes are periplasmic spaces. Immediately next to these are the growing cross walls composed of peptidoglycan, teichoic acid and protein.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2958.2007.05634.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 92

Metadata

Authors
Matias, V. R. F., & Beveridge, T. J.
Venue
Molecular Microbiology
Publisher
Wiley
Published
2007-03-16
Volume
64
Issue
1
Pages
195-206
ISSN
  • 0950-382X (ISSN-L)
  • 1365-2958
OpenAlex
W1587833696
Cited by
92
References
2
FWCI
4.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cryo‐electron microscopy of cell division in Staphylococcus aureus reveals a mid‐zone between nascent cross walls. https://app.cochat.ai/papers/10.1111/j.1365-2958.2007.05634.x
The paper
Matias, V. R. F., & Beveridge, T. J. (2007). Cryo‐electron microscopy of cell division in Staphylococcus aureus reveals a mid‐zone between nascent cross walls. Molecular Microbiology. https://doi.org/10.1111/j.1365-2958.2007.05634.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.