Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 329

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Intraluminal Multiple Electric Impedance Procedure for Measurement of Gastrointestinal Motility

Silny, Jiri · 1991 · Neurogastroenterology & Motility

Abstract

A new catheter‐related procedure for high‐resolution measurements of gastrointestinal motility is presented. The method is based on simultaneous acquisition of the electric impedance in the surrounding body volume conductor from a number of annular electrodes, successively arranged on the catheter. The impedance of a volume conductor around the catheter, consisting of a bolus, the organ wall, body fluids, and so forth, has a characteristic value for each segment and phase of contraction wave, as theoretical and experimental investigations revealed. A calculation on the basis of a simplified model reveals that the impedance changes as a logarithmic function of the bolus thickness, in which the highest sensitivity is advantageously obtained at a small lumen size and utilizing unipolar or bipolar electrode setups. The high resolution in time, space, and amplitude of the changes in the bolus shape allow us to use this impedance method for evaluation of functional stages in each measuring segment and of the beginning, end, and type of contraction wave, as well as their characteristics. The unique mechanical properties of the catheter (thinner than 3 mm, several meters long, flexible, closed surface) and the ability to distribute more than 32 measuring segments of different lengths on the catheter make this procedure suitable even for long‐term physiologic and pathologic studies of gastrointestinal motility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2982.1991.tb00061.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 329

Metadata

Authors
Silny, J.
Venue
Neurogastroenterology & Motility
Publisher
Wiley
Published
1991-09
Volume
3
Issue
3
Pages
151-162
ISSN
  • 1350-1925 (ISSN-L)
  • 1365-2982
OpenAlex
W2077292398
Cited by
329
References
2
FWCI
1.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intraluminal Multiple Electric Impedance Procedure for Measurement of Gastrointestinal Motility. https://app.cochat.ai/papers/10.1111/j.1365-2982.1991.tb00061.x
The paper
Silny, J. (1991). Intraluminal Multiple Electric Impedance Procedure for Measurement of Gastrointestinal Motility. Neurogastroenterology & Motility. https://doi.org/10.1111/j.1365-2982.1991.tb00061.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.