Effect of high‐frequency gastric electrical stimulation on gastric myoelectric activity in gastroparetic patients
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The aim of this study was to investigate the effect of gastric electrical stimulation (GES) on gastric myoelectric activity (GMA) and to identify possible mechanisms that could help explain how high‐frequency GES is effective in treating nausea and vomiting associated with gastroparesis. Fifteen gastroparetic patients who received high‐frequency GES were enrolled. Two pairs of temporary pacing wires were implanted on the serosa of the stomach along the greater curvature during surgery for placement of the permanent stimulation device. Two‐channel serosal recordings of GMA before and during GES were measured. A gastric emptying test and severity of nausea and vomiting were assessed at baseline and at 3 months of GES. Power spectral and cross correlation analyses revealed that impaired propagation of slow waves (50%), tachygastria (30%) and abnormal myoelectric responses to a meal (50%) were the main abnormalities observed at baseline. GES with a high frequency significantly enhanced the slow wave amplitude and propagation velocity, and resulted in a significant improvement in nausea and vomiting but did not entrain the gastric slow wave or improve gastric emptying after 3 months of GES.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soykan, I., Sivri, B., Sarosiek, I., Kiernan, B., & Mccallum, R. W. (1998) · Digestive Diseases and Sciences · doi:10.1023/a:1026665728213 · Cited by 575
Self-citation
Cited by
Forster, J., Damjanov, I., Lin, Z., Sarosiek, I., Wetzel, P., & McCallum, R. W. (2005) · Journal of Gastrointestinal Surgery · doi:10.1016/j.gassur.2004.10.001 · Cited by 251
Self-citationTreatment of Diabetic Gastroparesis by High-Frequency Gastric Electrical Stimulation
Lin, Z., Forster, J., Sarosiek, I., & McCallum, R. W. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1071 · Cited by 188
Self-citationGastric Electrical Stimulation Reduces Refractory Vomiting in a Randomized Crossover Trial
Ducrotte, P., Coffin, B., Bonaz, B., Fontaine, S., Bruley Des Varannes, S., Zerbib, F., Caiazzo, R., Grimaud, J. C., Mion, F., Hadjadj, S., et al. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.10.018 · Cited by 162
Diabetic Gastroparesis: Diagnosis and Management
Ma, J., Rayner, C. K., Jones, K. L., & Horowitz, M. (2009) · Drugs · doi:10.2165/00003495-200969080-00003 · Cited by 87
“Therefore, clinical research has focused on stimulation with short pulses, such as that approved by the US FDA, called Enterra therapy, delivering pulses at about 12 cycles per minute.([147-149]) Enterra therapy is performed by”
Different faces of gastroparesis
Bielefeldt, K., Raza, N., & Zickmund, S. L. (2009) · World Journal of Gastroenterology · doi:10.3748/wjg.15.6052 · Cited by 71
Metadata
- Authors
- Lin, Z., Forster, J., Sarosiek, I., & McCallum, R. W.
- Venue
- Neurogastroenterology & Motility
- Publisher
- Wiley
- Published
- 2004-04
- Volume
- 16
- Issue
- 2
- Pages
- 205-212
- ISSN
- 1350-1925 (ISSN-L)
- 1365-2982
- OpenAlex
- W2060881868
- Cited by
- 91
- References
- 1
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.