Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 316

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Gastric emptying of a non‐digestible solid: assessment with simultaneous SmartPill pH and pressure capsule, antroduodenal manometry, gastric emptying scintigraphy

Open access
Cassilly, D., Kantor, S., Knight, L. C., Maurer, A. H., Fisher, R. S., Semler, J., Parkman, H. P.·2008·Neurogastroenterology & Motility

Abstract

Abstract Gastric emptying of digestible solids occurs after trituration of food particles. Non‐digestible solids are thought to empty with phase III of the migrating motor complex (MMC). The aim of this study was to determine if a non‐digestible capsule given with a meal empties from the stomach with return of the fasting phase III MMC or during the fed pattern with the solid meal. Fifteen normal subjects underwent antroduodenal manometry and ingestion of a radiolabelled meal and SmartPill wireless pH and pressure capsule. In five subjects, emptying of the SmartPill was studied in the fasting period by ingesting the SmartPill with radiolabelled water. The SmartPill emptied from the stomach within 6 h in 14 of 15 subjects. SmartPill pressure recordings showed high amplitude phasic contractions prior to emptying. SmartPill gastric residence time (261 ± 22 min) correlated strongly with time to the first phase III MMC (239 ± 23 min; r = 0.813; P < 0.01) and correlated moderately with solid‐phase gastric emptying (r = 0.606 with T‐50% and r = 0.565 with T‐90%). Nine of 14 subjects emptied the capsule with a phase III MMC. In five subjects, the SmartPill emptied with isolated distal antral contractions. In five subjects ingesting only water, SmartPill gastric residence time (92 ± 44 min) correlated with the time to the first phase III MMC (87 ± 30 min; r = 0.979; P < 0.01). The non‐digestible SmartPill given with a meal primarily empties from the stomach with the return of phase III MMCs occurring after emptying the solid‐phase meal. However, in some subjects, the SmartPill emptied with isolated antral contractions, an unappreciated mechanism for emptying of a non‐digestible solid.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2982.2007.01061.x

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 316

Metadata

Authors
Cassilly, D., Kantor, S., Knight, L. C., Maurer, A. H., Fisher, R. S., Semler, J., & Parkman, H. P.
Venue
Neurogastroenterology & Motility
Publisher
Wiley
Published
2008-01-13
Volume
20
Issue
4
Pages
311-319
ISSN
  • 1350-1925 (ISSN-L)
  • 1365-2982
OpenAlex
W1607423153
Cited by
316
References
16
FWCI
15.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gastric emptying of a non‐digestible solid: assessment with simultaneous SmartPill pH and pressure capsule, antroduodenal manometry, gastric emptying scintigraphy. https://app.cochat.ai/papers/10.1111/j.1365-2982.2007.01061.x
The paper
Cassilly, D., Kantor, S., Knight, L. C., Maurer, A. H., Fisher, R. S., Semler, J., & Parkman, H. P. (2008). Gastric emptying of a non‐digestible solid: assessment with simultaneous SmartPill pH and pressure capsule, antroduodenal manometry, gastric emptying scintigraphy. Neurogastroenterology & Motility. https://doi.org/10.1111/j.1365-2982.2007.01061.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.