CoChat

Diagnosis and Immunotherapy of Mould Allergy: II. Reproducibility and Relationship between Skin Sensitivity Estimated by End‐Point Titration and Histamine Equivalent Reaction Using Skin Prick Test and Intradermal Test

Malling, H.‐J. · 1985 · Allergy
Cited by 50

The DOI matches its Crossref record.

Abstract

To determine reproducibility and the optimal way of expressing skin sensitivity, simultaneous skin prick tests (SPT) and intradermal tests (ICT) were performed on 25 mould‐allergic patients. The patients had a well‐documented history of allergy to Cladosporium and Alternaria and were tested with partially purified standardized extracts of these two mould species. Skin prick tests were carried out on the volar side of the forearm and intradermal tests on the backs of the patients. The skin tests were performed as titration using quadruplicate determinations of 10‐fold allergen dilutions. The area of the skin reactions measured by planimetry were plotted in a log‐log system as a function of the allergen concentration. The reproducibility (SD/mean area × 100%) of the ICTs was significantly higher than that of the SPTs (17% versus 29%). A very low reproducibility was found with wheal areas < 5 mm 2. The dose response curve of the SPT wheal area was steeper than that obtained with ICT, both concerning ICT wheal and flare. Increasing the allergen concentration with a factor 10 resulted in a doubling of the wheal area in SPT, in contrast to a factor 1.7 using ICT. The coefficient of correlation using linear regression on the dose response curve was always higher than 0.9 with SPT and ICT wheal, but significantly lower with ICT flare. Skin sensitivity was estimated as end‐point and histamine equivalent reaction. No significant correlation between SPT and ICT end‐point titration was found contrary to the histamine equivalent reaction. The difference in allergen concentration between end‐point and histamine equivalent reaction was a factor 500 (median) for both SPT and ICT. Due to the lower reproducibility of small skin reactions, the histamine equivalent reaction is to be preferred as an estimate of skin sensitivity. The simplicity and the steeper dose response curve of SPT outweigh the lower reproducibility compared with ICT, and with the use of potent allergen extracts, ICT has no advantages over SPT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1398-9995.1985.tb00247.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 50

Metadata

Authors
Malling, H. ‐.
Venue
Allergy
Publisher
Wiley
Published
1985-07
Volume
40
Issue
5
Pages
354-362
ISSN
  • 0105-4538 (ISSN-L)
  • 1398-9995
OpenAlex
W3024437608
Cited by
50
References
0
FWCI
3.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis and Immunotherapy of Mould Allergy: II. Reproducibility and Relationship between Skin Sensitivity Estimated by End‐Point Titration and Histamine Equivalent Reaction Using Skin Prick Test and Intradermal Test. https://app.cochat.ai/papers/10.1111/j.1398-9995.1985.tb00247.x
The paper
Malling, H. ‐. (1985). Diagnosis and Immunotherapy of Mould Allergy: II. Reproducibility and Relationship between Skin Sensitivity Estimated by End‐Point Titration and Histamine Equivalent Reaction Using Skin Prick Test and Intradermal Test. Allergy. https://doi.org/10.1111/j.1398-9995.1985.tb00247.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.