Standardization of the Prick Test: A Comparative Study of Three Methods
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The different needles and methods used in the prick test give rise to disparate results. This has significance when carrying out multi‐centre studies and when using the technique in the standardization of allergenic extracts. With test reliability as our objective, prick tests were carried out on 30 subjects: 10 patients sensitive to Dermatophagoides pteronyssinus received a glycerine extract of known allergenic potency, 10 healthy individuals 2.5% codeine phosphate in a glycerine solution, and another 10, histamine 1/1000. The total prick tests per individual was 27 with each of the needles employed (Allergy Pricker, the Morrow‐Brown needle and Insulin needle in accordance with Pepy's procedure). The tests were carried out systematically by three different testers, and the total number of prick tests performed was 810. With the Allergy Pricker, no differences were observed among results obtained by the same tester, nor when the results of the three testers were compared. With the Morrow‐Brown needle, the results varied in the same person and from one tester to another, and on many occasions the test was negative. With the Pepys method, no falsely negative results were obtained, but there was considerable variation in the size of the wheal. The variation coefficient is 41 % with the Allergy Pricker, and 115 % and 64 % with the Morrow‐Brown and Pepys method, respectively. In conclusion, the results obtained clearly indicate that the highest degree of reproducibility is obtained with the Allergy Pricker.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prick testing for allergens standardized by using a precision needle
BROWN, H. M., SU, S., & THANTREY, N. (1981) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.1981.tb01571.x · Cited by 43 · cited 2×
“The needles were: the Allergy-Pricker (Dome/Hollister-Stier) (3), the new MorrowBrown needle (1) and an Insulin needle, in accordance with the conventional method modified by Pepys (5, 6).”
Method
Cited by
Allergic Rhinitis and its Impact on Asthma (ARIA) 2008*
Bousquet, J., Khaltaev, N., Cruz, A. A., Denburg, J., Fokkens, W. J., Togias, A., Zuberbier, T., Baena‐Cagnani, C. E., Canonica, G. W., Van Weel, C., et al. (2008) · Allergy · doi:10.1111/j.1398-9995.2007.01620.x · Cited by 4,729
Allergic Rhinitis and Its Impact on Asthma
Bousquet, J., van Cauwenberge, P., & Khaltaev, N. (2001) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2001.118891 · Cited by 3,588
Allergic Rhinitis and its Impact on Asthma (ARIA) guidelines: 2010 Revision
Brożek, J. L., Bousquet, J., Baena-Cagnani, C. E., Bonini, S., Canonica, G. W., Casale, T. B., van Wijk, R. G., Ohta, K., Zuberbier, T., & Schünemann, H. J. (2010) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2010.06.047 · Cited by 1,813
Allergy Diagnostic Testing: An Updated Practice Parameter
Bernstein, I. L., Li, J. T., Bernstein, D. I., Hamilton, R., Spector, S. L., Tan, R., Sicherer, S., Golden, D. B. K., Khan, D. A., Nicklas, R. A., et al. (2008) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60305-5 · Cited by 723
McCann, W. A., & Ownby, D. R. (2002) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)62037-6 · Cited by 85
PHAGOO, S. B., WILSON, N. M., & SILVERMAN, M. (1991) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.1991.tb00851.x · Cited by 12
Metadata
- Authors
- Basomba, A., Sastre, A., Peláez, A., Romar, A., Campos, A., & GWarcía‐Villalmanzo, A.
- Venue
- Allergy
- Publisher
- Wiley
- Published
- 1985-08
- Volume
- 40
- Issue
- 6
- Pages
- 395-399
- ISSN
- 0105-4538 (ISSN-L)
- 1398-9995
- OpenAlex
- W1985991502
- Cited by
- 62
- References
- 1
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.