Passive IgE‐sensitization by blood transfusion
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: To study the mechanisms of passive sensitization of patients receiving plasma containing IgE antibodies to a defined allergen. Methods: When required for medical reasons, regular donor plasma with IgE antibodies to timothy grass allergen (8–205 kU A/l), was given. Kinetics of IgE antibodies in the recipients’ serum and his/her basophil allergen threshold sensitivity, CD‐sens, was monitored up to 2–3 weeks after transfusion. The IgE antibodies were quantitated by ImmunoCAP. The CD‐sens in plasma recipients, determined by CD63 up‐regulation, was measured by flow cytometry and compared to CD‐sens of patients with allergic asthma and/or rhinitis. Results: There was a significant correlation (r = 0.98; P < 0.001) between amount of IgE antibody given and recipient serum peak concentration. The T1/2 for IgE antibody in circulation was 1.13 days (95% confidence limit 0.35–1.91 days). The recipients became CD‐sens positive already 3 h after transfusion. The CD‐sens peak was observed after 3.4 days and the value were correlated (r = 0.68; P < 0.02) to the amount of IgE antibody transfused and were of the same magnitude as found in allergic patients. The T1/2 of CD‐sens indicated two populations of basophils; one with a CD‐sens decrease T1/2 of 4 days and one of 10 days. Conclusion: Transfused IgE antibodies will sensitize mast cells and basophils to CD‐sens levels similar to those of allergic patients. The recipients expressed ‘slow’ or ‘rapid’ CD‐sens decline, indicating two different basophil populations. After transfusion of plasma with >10 kU A/l IgE antibody the recipient could have allergen reactive basophils for up to 7 weeks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring human basophil activation via CD63 monoclonal antibody 435
Knol, E. F., Mul, F. P. J., Jansen, H., Calafat, J., & Roos, D. (1991) · Journal of Allergy and Clinical Immunology · doi:10.1016/0091-6749(91)90094-5 · Cited by 421 · cited 1×
“In the early 90s, it was reported that when the basophils empty their histamine containing granulae a structure on the granulae vesicle, CD63, becomes exposed on the cell surface (8).”
Background
Cited by
The clinical utility of basophil activation testing in diagnosis and monitoring of allergic disease
Hoffmann, H. J., Santos, A. F., Mayorga, C., Nopp, A., Eberlein, B., Ferrer, M., Rouzaire, P., Ebo, D. G., Sabato, V., Sanz, M. L., et al. (2015) · Allergy · doi:10.1111/all.12698 · Cited by 403
Self-citationAdverse effects of plasma transfusion
Pandey, S., & Vyas, G. N. (2012) · Transfusion · doi:10.1111/j.1537-2995.2012.03663.x · Cited by 351
Risk assessment in anaphylaxis: Current and future approaches
Simons, F. E. R., Frew, A. J., Ansotegui, I. J., Bochner, B. S., Golden, D. B. K., Finkelman, F. D., Leung, D. Y. M., Lotvall, J., Marone, G., Metcalfe, D. D., et al. (2007) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.05.001 · Cited by 289
Self-citationSantos, A. F., Alpan, O., & Hoffmann, H. (2021) · Allergy · doi:10.1111/all.14747 · Cited by 273
Santos, A. F., Du Toit, G., Douiri, A., Radulovic, S., Stephens, A., Turcanu, V., & Lack, G. (2015) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2014.09.001 · Cited by 196
Metadata
- Authors
- Johansson, S. G. O., Nopp, A., van Hage, M., Olofsson, N., Lundahl, J., Wehlin, L., Söderström, L., Stiller, V., & Öman, H.
- Venue
- Allergy
- Publisher
- Wiley
- Published
- 2005-08-02
- Volume
- 60
- Issue
- 9
- Pages
- 1192-1199
- ISSN
- 0105-4538 (ISSN-L)
- 1398-9995
- OpenAlex
- W2012682704
- Cited by
- 120
- References
- 1
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.