The DOI matches its Crossref record.
High‐resolution, high‐throughput HLA genotyping by next‐generation sequencing
Open accessAbstract
The human leukocyte antigen (HLA) class I and class II loci are the most polymorphic genes in the human genome. Hematopoietic stem cell transplantation requires allele‐level HLA typing at multiple loci to select the best matched unrelated donors for recipient patients. In current methods for HLA typing, both alleles of a heterozygote are amplified and typed or sequenced simultaneously, often making it difficult to unambiguously determine the sequence of the two alleles. Next‐generation sequencing methods clonally propagate in parallel millions of single DNA molecules, which are then also sequenced in parallel. Recently, the read lengths obtainable by one such next‐generation sequencing method (454 Life Sciences, Inc.) have increased to >250 nucleotides. These clonal read lengths make possible setting the phase of the linked polymorphisms within an exon and thus the unambiguous determination of the sequence of each HLA allele. Here we demonstrate this capacity as well as show that the throughput of the system is sufficiently high to enable a complete, 7‐locus HLA class I and II typing for 24 or 48 individual DNAs in a single GS FLX sequencing run. Highly multiplexed amplicon sequencing is facilitated by the use of sample‐specific internal sequence tags (multiplex identification tags or MIDs) in the primers that allow pooling of samples yet maintain the ability to assign sequences to specific individuals. We have incorporated an HLA typing software application developed by Conexio Genomics (Freemantle, Australia) that assigns HLA genotypes for these 7 loci (HLA‐A, ‐B, ‐C, DRB1, DQA1, DQB1, DPB1), as well as for DRB3, DRB4, and DRB5 from 454 sequence data. The potential of this HLA sequencing system to analyze chimeric mixtures is demonstrated here by the detection of a rare HLA‐B allele in a mixture of two homozygous cell lines (1/100), as well as by the detection of the rare nontransmitted maternal allele present in the blood of a severe combined immunodeficiency disease syndrome (SCIDS) patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Next-generation sequencing technologies: An overview
Hu, T., Chitnis, N., Monos, D., & Dinh, A. (2021) · Human Immunology · doi:10.1016/j.humimm.2021.02.012 · Cited by 949
OptiType: precision HLA typing from next-generation sequencing data
Szolek, A., Schubert, B., Mohr, C., Sturm, M., Feldhahn, M., & Kohlbacher, O. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu548 · Cited by 769
Major Histocompatibility Complex Genomics and Human Disease
Trowsdale, J., & Knight, J. C. (2013) · Annual Review of Genomics and Human Genetics · doi:10.1146/annurev-genom-091212-153455 · Cited by 759
Avci, F. Y., Li, X., Tsuji, M., & Kasper, D. L. (2011) · Nature Medicine · doi:10.1038/nm.2535 · Cited by 366
Cost-efficient high-throughput HLA typing by MiSeq amplicon sequencing
Lange, V., Böhme, I., Hofmann, J., Lang, K., Sauter, J., Schöne, B., Paul, P., Albrecht, V., Andreas, J. M., Baier, D. M., et al. (2014) · BMC Genomics · doi:10.1186/1471-2164-15-63 · Cited by 271
Metadata
- Authors
- Bentley, G., Higuchi, R., Hoglund, B., Goodridge, D., Sayer, D., Trachtenberg, E. A., & Erlich, H. A.
- Venue
- Tissue Antigens
- Publisher
- Wiley
- Published
- 2009-10-14
- Volume
- 74
- Issue
- 5
- Pages
- 393-403
- ISSN
- 0001-2815 (ISSN-L)
- 1399-0039
- OpenAlex
- W2096475535
- Cited by
- 185
- References
- 0
- FWCI
- 9.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐resolution, high‐throughput HLA genotyping by next‐generation sequencing. https://app.cochat.ai/papers/10.1111/j.1399-0039.2009.01345.x
- The paper
- Bentley, G., Higuchi, R., Hoglund, B., Goodridge, D., Sayer, D., Trachtenberg, E. A., & Erlich, H. A. (2009). High‐resolution, high‐throughput HLA genotyping by next‐generation sequencing. Tissue Antigens. https://doi.org/10.1111/j.1399-0039.2009.01345.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.