CoChat

Hemoglobin glycation index: a robust measure of hemoglobin A1c bias in pediatric type 1 diabetes patients

Soros, Arlette A, Chalew, Stuart A, McCarter, Robert J, Shepard, Rachel, Hempe, James M · 2010 · Pediatric Diabetes
Cited by 89

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The hemoglobin glycation index (HGI) assesses biological variation in A1c after accounting for the effect of mean blood glucose (MBG). Previous studies minimized analytical variation that could mask biological variation and showed that HGI was consistent within individuals over time and positively associated with risk for microvascular complications. We tested the hypothesis that biological variation in A1c can be assessed by HGI calculated using routine MBG and A1c data obtained from a typical diabetes clinic. METHODS: Self-monitored MBG and A1c were collected from charts of 202 pediatric type 1 diabetes patients attending 1612 clinic visits over 6 yr. Predicted A1c was calculated from the linear regression equation of A1c on MBG in the study population. HGI was calculated by subtracting predicted A1c from observed A1c. Patients were divided into low, moderate, and high HGI tertile groups. RESULTS: Patients used 12 models of glucose meters. Download protocols varied with clinical practice over time. A1c was measured by multiple assays and laboratories. Despite this analytical heterogeneity, HGI was significantly different between individuals and correlated within individuals. MBG (mean ± SD, mg/dL) was similar in the low (186 ± 31), moderate (195 ± 28), and high (199 ± 42) HGI groups. A1c (%) was significantly different (p < 0.0001) in the low (7.6 ± 0.7), moderate (8.4 ± 0.7), and high (9.6 ± 1.1) HGI groups. CONCLUSION: Biological variation in A1c is a robust quantitative trait that can be assessed using HGI calculated from routine clinic data. This suggests that HGI could be used clinically for more personalized assessment of complications risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1399-5448.2009.00630.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 89

Metadata

Authors
Soros, A. A., Chalew, S. A., McCarter, R. J., Shepard, R., & Hempe, J. M.
Venue
Pediatric Diabetes
Published
2010-01-18
Volume
11
Issue
7
Pages
455-461
ISSN
1399-543X (ISSN-L)
OpenAlex
W2044800162
Cited by
89
References
1
FWCI
1.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemoglobin glycation index: a robust measure of hemoglobin A1c bias in pediatric type 1 diabetes patients. https://app.cochat.ai/papers/10.1111/j.1399-5448.2009.00630.x
The paper
Soros, A. A., Chalew, S. A., McCarter, R. J., Shepard, R., & Hempe, J. M. (2010). Hemoglobin glycation index: a robust measure of hemoglobin A1c bias in pediatric type 1 diabetes patients. Pediatric Diabetes. https://doi.org/10.1111/j.1399-5448.2009.00630.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.