Platelet concentrates transfusion in cardiac surgery and platelet function assessment by multiple electrode aggregometry
Abstract
Background: Platelet dysfunction contributes to the pathophysiology of bleeding complications during and after cardiac surgery. In most surgical institutions, no peri‐operative point‐of‐care monitoring of platelet function is used. We evaluated the usefulness of the Multiplate® platelet function analyser based on impedance aggregometry for identifying groups of patients at a high risk of transfusion of platelet concentrates (PC). Methods: Platelet function parameters were determined in 60 patients before and after routine cardiac surgery. Impedance aggregometry measurements were performed on Multiplate® using ADP (ADPtest), collagen (COLtest) and thrombin receptor activating peptide (TRAPtest) as platelet activators. The correlations between the aggregometry results and the transfusion of PC were calculated. The results of the aggregation tests were also divided into tertiles and the differences in PC transfusion between the low and the high tertile were assessed. Results: Low aggregometry delimited groups of patients with significantly higher PC transfusion. In the receiver operating characteristic curve, low pre‐operative aggregation in the ADPtest identified patients with high total transfusion of PC (area under the curve 0.74, P=0.001), while the ADPtest performed at the end of the operation identified patients with high PC transfusion on the intensive care unit (ICU) (area under the curve 0.76, P=0.002). Conclusions: Near‐patient platelet aggregation may allow the identification of patients with enhanced risk of PC transfusion, both pre‐operatively and upon arrival on the ICU.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
POC tests can detect tissue factor expression on circulating cells, fibrin polymerization disorders (e.g., from colloid infusion), hyperfibrinolysis, and platelet dysfunction due to cardiopulmonary bypass or antiplatelet drugs.
“Therefore, they are able to detect tissue factor expression on circulating cells, fibrin polymerization disorders, e.g., due to colloid infusion, hyperfibrinolysis, as well as platelet dysfunction due to CPB or antiplatelet drugs.38 -44”
From Point-of-Care Testing: A Prospective, Randomized Clinical Trial of Efficacy in Coagulopathic Cardiac Surgery Patients (2012) · cites this paper as [43]
Cited by
Sorted by citations
Weber, C. F., Görlinger, K., Meininger, D., Herrmann, E., Bingold, T., Moritz, A., Cohn, L. H., & Zacharowski, K. (2012) · Anesthesiology · doi:10.1097/aln.0b013e318264c644 · Cited by 625 · see citing works
- Authors
- Rahe‐Meyer, N., Winterhalter, M., Boden, A. G., FROEMKE, C., Piepenbrock, S., Calatzis, A., & Solomon, C.
- Affiliations
- Medizinische Hochschule Hannover (DE)
- Ludwig-Maximilians-Universität München (DE)
- Corresponding author
- Niels Rahe‐Meyer
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 2009-01-19
- Volume
- 53
- Issue
- 2
- Pages
- 168-175
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W1503020567
- Cited by
- 147
- References
- 0
- Citations by year
- 2025: 6 · 2023: 1 · 2022: 2 · 2021: 7 · 2020: 10 · 2019: 3 · 2018: 6 · 2017: 10 · 2016: 14 · 2015: 12 · 2014: 12 · 2013: 13 · 2012: 17
- FWCI
- 11.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Acta Anaesthesiologica Scandinavica (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Biochemistry › Blood transfusion and management
- Health Sciences › Medicine › Hematology › Platelet Disorders and Treatments
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Trauma, Hemostasis, Coagulopathy, Resuscitation
- Keywords
- cardiac surgery, impedance aggregometry, Multiplate, point-of-care monitoring, platelet dysfunction, bleeding complications, thrombin receptor activating peptide, preoperative risk stratification, intensive care unit
- MeSH terms
- Adenosine Diphosphate, Aged, Cardiopulmonary Bypass, Collagen, Electrodes, Female, Cardiac Surgical Procedures, Humans, Male, Middle Aged, Pilot Projects, Platelet Aggregation, Platelet Function Tests, Risk, Platelet Activation, Single-Blind Method, Blood Loss, Surgical, Electric Impedance, Platelet Transfusion, Receptors, Thrombin, Postoperative Hemorrhage
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review