Metallocytochromes c : Characterization of Electronic Absorption and Emission Spectra of Sn4+ and Zn2+ Cytochromes c
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Tin (Sn4+) and zinc (Zn2+) derivatives of horse heart cytochrome c have been prepared and their optical spectra have been characterized. Zinc cytochrome c has visible absorption maxima at 549 and 585 nm and Soret absorption at 423 nm. Tin cytochrome c shows visible absorption maxima at 536 and 574 nm and Soret absorption at 410 nm. Unlike iron cytochrome c in which the emission spectrum of the porphyrin is almost completely quenched by the central metal, the zinc and tin derivatives of cytochrome c are both fluorescent and phosphorescent. The fluorescence maxima of zinc cytochrome c are at 590 and 640 nm and the fluorescence lifetime is 3.2 ns. The fluorescence maxima of Sn cytochrome are at 580 and 636 nm and the fluorescence lifetime is under 1 ns. The quantum yield of fluorescence is Zn greater than Sn while the quantum yield of phosphorescence is Sn greater than Zn. at 77 K the fluorescence and phosphorescence emission spectra of Sn and Zn cytochrome c show evidence of resolution into vibrational bands. The best resolved bands occur at frequency differences 750 cm-1 and 1540--1550 cm-1 from the O-O transition. These frequencies correspond with those obtained by resonance Raman spectroscopy for in-plane deformations of the porphyrin macrocycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
Molecular Spectra and Molecular Structure
Huber, K. P., & Herzberg, G. (1979) · Springer eBooks · doi:10.1007/978-1-4757-0961-2 · Cited by 16,094
Gouterman, M. (1961) · Journal of Molecular Spectroscopy · doi:10.1016/0022-2852(61)90236-3 · Cited by 2,227
Study of the Effects of Substitution on the Absorption Spectra of Porphin
Gouterman, M. (1959) · The Journal of Chemical Physics · doi:10.1063/1.1730148 · Cited by 1,001
Appendix—Spectrum of horse-heart cytochrome c
Margoliash, E., & Frohwirt, N. (1959) · Biochemical Journal · doi:10.1042/bj0710570 · Cited by 805
Seybold, P. G., & Gouterman, M. (1969) · Journal of Molecular Spectroscopy · doi:10.1016/0022-2852(69)90335-x · Cited by 672
Resonance Raman spectra of heme proteins. Effects of oxidation and spin state
Spiro, T. G., & Strekas, T. C. (1974) · Journal of the American Chemical Society · doi:10.1021/ja00809a004 · Cited by 580
Porphyrins XVII. Vapor absorption spectra and redox reactions: Tetraphenylporphins and porphin
Edwards, L., Dolphin, D. H., Gouterman, M., & Adler, A. D. (1971) · Journal of Molecular Spectroscopy · doi:10.1016/0022-2852(71)90090-7 · Cited by 310
Studies on Cobalt Myoglobins and Hemoglobins
Yonetani, T., Yamamoto, H., & Woodrow, G. V. (1974) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)42984-0 · Cited by 216
Vibronic Coupling. VI. Vibronic Borrowing in Cyclic Polyenes and Porphyrin
Perrin, M. H., Gouterman, M., & Perrin, C. L. (1969) · The Journal of Chemical Physics · doi:10.1063/1.1670879 · Cited by 176
Heavy Metal Prosthetic Groups and Enzyme Action
Warburg, O. H. (1950) · Soil Science · doi:10.1097/00010694-195008000-00020 · Cited by 149
Cytochrome c Interaction with Membranes
Vanderkooi, J. M., & Erecińska, M. (1975) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1975.tb20992.x · Cited by 119
Self-citationCytochrome c interaction with membranes
Vanderkooi, J. M., Erecińska, M., & Chance, B. (1973) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(73)90052-0 · Cited by 101
Self-citation
Cited by
Fluorescence Techniques for Studying Protein Structure
Eftink, M. R. (1991) · Methods of Biochemical Analysis · doi:10.1002/9780470110560.ch3 · Cited by 504
Kluck, R. M. (1997) · The EMBO Journal · doi:10.1093/emboj/16.15.4639 · Cited by 383
Phospholipid-Cytochrome c Interaction
Tuominen, E. K. J., Wallace, C. J. A., & Kinnunen, P. K. J. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m200056200 · Cited by 309
Esteve‐Núñez, A., Sosnik, J., Visconti, P., & Lovley, D. R. (2008) · Environmental Microbiology · doi:10.1111/j.1462-2920.2007.01470.x · Cited by 226
“Previous studies reported that cytochrome c could emit fluorescence in the red range (620–680 nm) if Fe is released from the haem group (Fraaije et al., 1990) or replaced by Sn or Zn (Vanderkooi et al., 1976).”
BackgroundClark, R. A., & Bowden, E. F. (1997) · Langmuir · doi:10.1021/la960650+ · Cited by 179
Metadata
- Authors
- VANDERKOOI, J. M., ADAR, F., & ERECINSKA, M.
- Venue
- European Journal of Biochemistry
- Publisher
- Wiley
- Published
- 1976-05
- Volume
- 64
- Issue
- 2
- Pages
- 381-387
- ISSN
- 0014-2956 (ISSN-L)
- 1432-1033
- OpenAlex
- W2071063746
- Cited by
- 164
- References
- 13
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.