The evolving role of alemtuzumab (Campath-1H) for immunosuppressive therapy in organ transplantation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Alemtuzumab is a monoclonal anti-CD52 antibody, which has been used extensively off label in solid organ transplantation. Its primary use has been as an induction agent at the time of organ transplantation, although there is limited experience using it to treat steroid-resistant rejection. Prolonged lymphocyte depletion can be expected following alemtuzumab treatment even with one dose of 30 mg intravenously. The nature and kinetics of lymphocyte repopulation depend on the maintenance immunosuppression being administered. In comparison with Thymoglobulin, a polyclonal depleting antibody preparation, alemtuzumab offers significant practical benefits with lower cost, fewer side effects in administration, and no specific issues with i.v. access. The risks and benefits of depleting induction agents, such as alemtuzumab, are compared with nondepleting agents, such as anti-CD25 induction therapy. While the majority of experience in solid organ transplantation has been in kidney transplantation, there is more limited experience in liver, pancreas, islet, small bowel, and lung transplantation. We herein review some of the lessons learned from clinical experience to date in solid organ transplantation using alemtuzumab as an immunosuppressant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pulsed monoclonal antibody treatment and autoimmune thyroid disease in multiple sclerosis
Coles, A. J., Wing, M., Smith, S., Coraddu, F., Greer, S., Taylor, C., Weetman, A., Hale, G., Chatterjee, V. K., Waldmann, H., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)02429-0 · Cited by 453 · cited 1×
“[17] reported a 33% incidence of autoimmune thyroid disease in patients treated with five doses of alemtuzumab for multiple sclerosis.”
Background
Cited by
Prerequisites for cytokine measurements in clinical trials with multiplex immunoassays
de Jager, W., Bourcier, K., Rijkers, G. T., Prakken, B. J., & Seyfert-Margolis, V. (2009) · BMC Immunology · doi:10.1186/1471-2172-10-52 · Cited by 427
CD3-specific antibodies: a portal to the treatment of autoimmunity
Chatenoud, L., & Bluestone, J. A. (2007) · Nature Reviews Immunology · doi:10.1038/nri2134 · Cited by 388
A comprehensive review of immunosuppression used for liver transplantation
Mukherjee, S., & Mukherjee, U. (2009) · Journal of Transplantation · doi:10.1155/2009/701464 · Cited by 140
“A further distinguishing feature of alemtuzumab is its ability to deplete lymphocytes from both the blood and lymph nodes with the exception of plasma and memory cells [105].”
BackgroundPreoperative CD52 Level Predicts Graft Survival following Kidney Transplantation
Ramouz, A., Nikbakhsh, R., Khajeh, E., Sadeghi, M., Daniel, V., Schmitzler, P., Morath, C., Zeier, M., Mehrabi, A., & Oweira, H. (2022) · BioMed Research International · doi:10.1155/2022/8949919 · Cited by 2
Clinical Aspects of Liver Transplantation
Mangus, R. S., & Tector, A. J. (2011) · Practical Hepatic Pathology: A Diagnostic Approach · doi:10.1016/b978-0-443-06803-4.00041-1 · Cited by 1
Metadata
- Authors
- Magliocca, J. F., & Knechtle, S. J.
- Venue
- Transplant International
- Publisher
- Frontiers Media SA
- Published
- 2006-09
- Volume
- 19
- Issue
- 9
- Pages
- 705-714
- ISSN
- 0934-0874 (ISSN-L)
- 1432-2277
- OpenAlex
- W2065448696
- Cited by
- 141
- References
- 1
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.