Electrogastrography: Basic knowledge, recording, processing and its clinical applications
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The slow wave (SW) of the gastrointestinal (GI) tract mainly functions to trigger the onset of spike to elicit smooth muscle contraction, which provides the essential power of motility. Smooth muscle myogenic control activity or SW is believed to originate in the interstitial cells of Cajal (ICC). The electrical coupling promotes interaction between muscle cells, and ICC additionally contribute to SW rhythmicity. Stomach SW originates in the proximal body showing the continuous rhythmic change in the membrane potential and propagates normally to the distal antrum with a regular rhythm of approximately 3 c.p.m. A technique using electrodes positioned on the abdominal skin to pick up stomach rhythmic SW refers to electrogastrography (EGG). The stomach SW amplitude is very weak, while many visceral organs also produce rhythmic electricities, for example heartbeat, respiration, other organs of the GI tract and even body movements. Thus noise other than SW should be filtered out during the recording, while motion artifacts are visually examined and deleted. Finally, the best signal among all recordings is selected to compute EGG parameters based on spectral analysis. The latter is done not only to tranform frequency domain to time domain but also to provide information of time variability in frequency. Obtained EGG parameters include dominant frequency/power, % normal rhythm, % bradygastria, % tachygastria, instability coefficient and power ratio. Clinical experience in EGG has been markedly accumulated since its rapid evolution. In contrast, lack of standardized methodology in terms of electrode positions, recording periods, test meals, analytic software and normal reference values makes the significance of EGG recording controversial. Unlike imaging or manometrical studies, stomach motility disorders are not diagnosed based only on abnormal EGG parameters. Limitations of EGG recording, processing, computation, acceptable normal parameters, technique and reading should be known to conduct subjective assessments when EGG is used to resolve stomach dysfunction. Understanding basic SW physiology, recording methodology and indications may open EGG as a new domain to approach the stomach motor dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sanders, K. (1996) · Gastroenterology · doi:10.1053/gast.1996.v111.pm8690216 · Cited by 959
Cited by
Bharucha, A. E., Kudva, Y. C., & Prichard, D. O. (2019) · Endocrine Reviews · doi:10.1210/er.2018-00161 · Cited by 252
Wolpert, N., Rebollo, I., & Tallon‐Baudry, C. (2020) · Psychophysiology · doi:10.1111/psyp.13599 · Cited by 96
Abnormal gastric myoelectrical activity in postural tachycardia syndrome
Seligman, W. H., Low, D. A., Asahina, M., & Mathias, C. J. (2013) · Clinical Autonomic Research · doi:10.1007/s10286-012-0185-3 · Cited by 33
“In healthy subjects, gastric myoelectrical activity is composed of ‘gastric slow waves’ and spike/second potentials at a frequency of 3 cycles per min (cpm) [9].”
Background
Metadata
- Authors
- CHANG, F.
- Venue
- Journal of Gastroenterology and Hepatology
- Publisher
- Wiley
- Published
- 2005-02-25
- Volume
- 20
- Issue
- 4
- Pages
- 502-516
- ISSN
- 0815-9319 (ISSN-L)
- 1440-1746
- OpenAlex
- W2093665896
- Cited by
- 115
- References
- 1
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrogastrography: Basic knowledge, recording, processing and its clinical applications. https://app.cochat.ai/papers/10.1111/j.1440-1746.2004.03751.x
- The paper
- CHANG, F. (2005). Electrogastrography: Basic knowledge, recording, processing and its clinical applications. Journal of Gastroenterology and Hepatology. https://doi.org/10.1111/j.1440-1746.2004.03751.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.